Step 5: Create a Send Port to Deliver Acknowledgments to the ADT System Using the File Adapter
In this step, you create the send port to generate acknowledgments using the File adapter.
To create the Tutorial_sendAck_ADT send port
Using Windows Explorer, create the <drive:>\Program Files\Microsoft BizTalk <version> Accelerator for HL7\SDK\End-to-End Tutorial\Tutorial_sendAck_ADT folder.
In the BizTalk Server Administration Console, right-click Send Ports, point to New, and then click Static One-way Send Port.
In the Send Port Properties dialog box, do the following:
Use this To do this Name Type Tutorial_sendAck_ADT. Transport type Select FILE from the drop-down list. Configure Click Configure to open the File Transport Properties dialog box. In the FILE Transport Properties dialog box, do the following and then click OK.
Use this To do this Destination folder Browse to <drive:>\Program Files\Microsoft BizTalk <version> Accelerator for HL7\SDK\End-to-End Tutorial\Tutorial_sendAck_ADT. File name Type %MessageID%.txt (replace the .xml extension with the .txt extension). In the Send Port Properties dialog box, for Send pipeline, select BTAHL72XPipelines.BTAHL72XSendPipeline.
In the left pane, click Filters, and then do the following:
Note
The first filter means that you are subscribing for the acknowledgment message. The second filter means that you are subscribing to the acknowledgment that is destined for the publisher Tutorial_ADTSystem.
Click OK when you are ready to continue.
Use this To do this Property Click the field under Property, and then select BTS.MessageType from the drop-down list. Operator Select == from the drop-down list. Value Type http://microsoft.com/HealthCare/HL7/2X#ACK_24_GLO_DEF
.Group By Select OR from the drop-down list. Property (second line) Click the field under Property, and then select BTS.MessageType from the drop-down list. Operator Select == from the drop-down list. Value Type http://microsoft.com/HealthCare/HL7/2X#ACK_25_GLO_DEF
Group By Select AND from the drop-down list. Property Under the first property, click the blank box, and then select BTAHL7Schemas.MSH5_1. Operator Select == from the drop-down list. Value Type Tutorial_ADTSystem. Note
For the send port Tutorial_sendAck_ADT, BTAHL7 drops the acknowledgments at the file drop location <drive>:\Program Files\Microsoft BizTalk <version> Accelerator for HL7\SDK\End-to-End Tutorial\Tutorial_sendAck_ADT.
Click Apply, and then click OK.
In the Administration Console, click Send Ports, right-click Tutorial_sendAck_ADT, and then click Start.
Proceed to Step 6: Create a Send Port to Deliver the ADT^A03 Message to the RX System Using the File Adapter.