Product Configuration Synchronous Execution

This blog post describes an new way of interacting synchronously from code with the
Constraint-Based Product Configurator which has been introduced in Microsoft
Dynamics AX 2012 R3 CU8.

 

Scenario

The scenario that drove the introduction of this feature can be described as follows:

 

An external 3rd party sales configurator outside of Microsoft Dynamics AX 2012 is used to
assign values to a subset of attributes(a partially configured order), from
which the remaining mandatory attributes can have their values deduced using
the Microsoft Dynamics AX 2012 Configurator, thereby completing the order.

 

 

Once the all the values have been deduced, assuming all values are valid, they can be passed on
to the back end configuration module, which will create the BOM and potentially
the Route (if the model has a Route).

 

Implementation

Included in Microsoft Dynamics AX 2012 R3 CU 8 is a new derived version of the PCRuntimeConfigurator class, named PCRuntimeSynchronousConfigurator.

This class is designed, as the name indicates, for synchronous interaction with the .NET
Configurator component.

 

The configure method on the class is the method
which exposes the new functionality added to the .NET Configurator to Xpp. The
method takes three arguments; the model as xml, the attribute assignments as
xml and a the number of milliseconds which can be used before a timeout occur.
The return of the method is a IsConfigurationComplete enum value, from which
result of the configuration can be determined;

 

  • Complete
    • The configuration is complete
  • Incomplete
    • One or more mandatory attributes does not have a value
  • Timeout
    • The configurator was not able to complete the configuration within the given timeout limit
  • Contradiction
    • One or more constraints have been violated

 

Note:

The PCRuntimeSynchronuosConfigurator class exposes
the functionality required by the .NET configurator component to support the
above scenario but it is not yet integrated with any order (sales, production
etc) or product variant creation nor is it integrated with the BOM and Route
generation.

 

KB Article with number 3028719 should be Applied on top of R3 CU 8 as it addresses a stability issue in the solution.

 Example

 In this example values are passed from the simulated 3rd party configurator into Dynamics AX 2012 through a web service, as illustrated below:

 

 

To expose the PCRuntimeSynchronousConfigurator class through
a web service, we start by introducing a new class
PCTechDemoService which implements a method with the SysEntryPointAttribute code attribute, which is
needed for a method to be exposed as a web service.

 

In this simple implementation the example method looks like this:

 

[SysEntryPointAttribute(true)]

public boolean configure(PCName _modelName, str _xmlValues)

{

    boolean ret;

    str values;

 

    PCRuntimeSynchronousConfigurator configurator  = PCRuntimeSynchronousConfigurator::construct();

    PCProductConfigurationModel productConfigurationModel  =  PCProductConfigurationModel::findByName(_modelName);

    values = '<Assignments>' + _xmlValues  + '</Assignments>';

   
if(configurator.configure(productConfigurationModel.getXML(), values,120000) == Microsoft.Dynamics.Ax.Frameworks.Controls.ProductConfiguration.IsConfigurationComplete::Complete)

    {

        ret = true;

    }

 

    return ret;

}

Now we can create a Service in the AOT which uses the PCTechDemoService
class and its configure method as an operation. To use this service, it needs
to be put in a service group, which can then be deployed.

 

 

To test the service, navigate to System administration > Services and Application Integration Framework > Inbound ports. Here we find our new PCTechDemoServiceGroup, copy the WSDL URI value.

 

 

 

Open Visual Studio Command prompt and type:

Wcftestclient <Your WSDL URI>

 

This will open the WCF test client where we can now see our web service.

 

For the demo data set I have used, I will use the following argument values

 

_modelName : 20001

_xmlValues : <Assignment xPath="powerCableLength" value="10"/><Assignment xPath="videoSystem/television/size" value="42" />

 

Note: the xPath mechanism used to identify the attributes in model.

 

 

If you are familiar with the 20001(Home theater system) model, you will know that it has just two
mandatory attributes which are not assigned by defaults; the powerCableLength
on the root component and the size on the television component.

 

Attached you will find an Xpp project with code used for the example.

 

Enjoy

 

 

 

Demo.zip

Comments

  • Anonymous
    July 05, 2015
    Hi Dennis, The model you are referring to doesn't exist anymore in the recent demo data. There's no '20001' model anymore (it used to exist) in the most recent demo db that is used for Azure hosted demo environments. i tried an existing model and modified the parameters list but then I got what looked like a 'timeout'. I also requested the fix you mentioned and received a url but that didn't work. As a result, I didn't get this to work. Anybody else did? Steven

  • Anonymous
    July 13, 2015
    Hi Dennis, Does AX2012 R3 have the feature of using arrays in calculation or do we know if we can deploy with Configurator like it used to be in product builder. Thanks,

  • Anonymous
    July 27, 2015
    Hi Steven, thank you for your comment. I have included the '20001' model in the Demo.zip file, such that you can import it and try the sample code. If you continue to experience a timeout, and you have applied the mentioned change, then I would ask that you open an issue through our support channel. Best regards Dennis

  • Anonymous
    July 27, 2015
    Hi Hemant, thank you for your comment. The Constraint-based configurator does not have arrays like Product Builder. It is discouraged to deploy with Product Builder if possible as Product Builder will not be part of next major release of Microsoft Dynamics AX. Best regards Dennis