Compartir a través de


WSARecv (Compact 2013)

3/26/2014

This function receives data from a connected socket.

Syntax

int WSARecv(
  SOCKET s,
  LPWSABUF lpBuffers,
  DWORD dwBufferCount,
  LPDWORD lpNumberOfBytesRecvd,
  LPDWORD lpFlags,
  LPWSAOVERLAPPED lpOverlapped,
  LPWSAOVERLAPPED_COMPLETION_ROUTINE lpCompletionRoutine
);

Parameters

  • s
    [in] Descriptor identifying a connected socket.
  • lpBuffers
    [in, out] Pointer to an array of WSABUF structures. Each WSABUF structure contains a pointer to a buffer and the length of the buffer.
  • dwBufferCount
    [in] Number of WSABUF structures in the lpBuffers array.
  • lpNumberOfBytesRecvd
    [out] Pointer to the number of bytes received by this call if the receive operation completes immediately.
  • lpFlags
    [in, out] Pointer to flags.
  • lpOverlapped
    [in] Pointer to a WSAOVERLAPPED structure (ignored for nonoverlapped sockets).
  • lpCompletionRoutine
    [in] Pointer to the completion routine called when the receive operation has been completed (ignored for nonoverlapped sockets).

Return Value

If no error occurs and the receive operation has completed immediately, this function returns zero. The overlapped structures are updated with the receive results, and the associated event is signalled.

In Windows Embedded Compact, the completion object will not be signalled. If an error occurs, a value of SOCKET_ERROR is returned, and a specific error code can be retrieved by calling the WSAGetLastError function. The error code WSA_IO_PENDING indicates that the overlapped operation has been successfully initiated and that completion will be indicated at a later time. Any other error code indicates that the overlapped operation was not successfully initiated and no completion indication will occur.

The following table shows a list of possible error codes.

Error code

Description

WSANOTINITIALISED

A successful WSAStartup call must occur before using this function.

WSAENETDOWN

The network subsystem has failed.

WSAENOTCONN

The socket is not connected.

WSAEINTR

The socket was closed.

WSAEINPROGRESS

A blocking Winsock call is in progress, or the service provider is still processing a callback function.

WSAENETRESET

The connection has been broken due to keep-alive activity detecting a failure while the operation was in progress.

WSAENOTSOCK

The descriptor is not a socket.

WSAEFAULT

The lpBuffers parameter is not completely contained in a valid part of the user address space.

WSAEOPNOTSUPP

MSG_OOB was specified, but the socket is not stream style such as type SOCK_STREAM, out of band (OOB) data is not supported in the communication domain associated with this socket, or the socket is unidirectional and supports only send operations.

WSAESHUTDOWN

The socket has been shut down. It is not possible to call WSARecv on a socket after shutdown has been invoked with how set to SD_RECEIVE or SD_BOTH.

WSAEWOULDBLOCK

For overlapped sockets, there are too many outstanding overlapped I/O requests. For nonoverlapped sockets, the socket is marked as nonblocking and the receive operation cannot be completed immediately.

WSAEMSGSIZE

The message was too large to fit into the specified buffer and (for unreliable protocols only) any trailing portion of the message that did not fit into the buffer has been discarded.

WSAEINVAL

The socket has not been bound (for example, with bind (Windows Sockets)).

WSAECONNABORTED

The virtual circuit was terminated due to a time-out or other failure.

WSAECONNRESET

The virtual circuit was reset by the remote side.

WSAEDISCON

Socket s is message-oriented and the virtual circuit was gracefully closed by the remote side.

WSA_IO_PENDING

An overlapped operation was successfully initiated and completion will be indicated at a later time.

WSA_OPERATION_ABORTED

The overlapped operation has been canceled due to the closure of the socket.

Remarks

This function provides functionality over and above the standard recv function in the following three important areas:

  • It can be used in conjunction with overlapped sockets to perform overlapped receive operations.
  • It allows multiple receive buffers to be specified, enabling a scatter/gather type of I/O.
  • The lpFlags parameter is both an input and output parameter, allowing applications to sense the output state of the MSG_PARTIAL flag bit. However, the MSG_PARTIAL flag bit is not supported by all protocols.

This function is used on connected sockets or bound connectionless sockets specified by the s parameter and is used to read incoming data. The socket's local address must be known. For server applications, this is usually done explicitly through bind (Windows Sockets) or implicitly through the accept (Windows Sockets) or WSAAccept function. Explicit binding is discouraged for client applications. For client applications, the socket can become bound implicitly to a local address through the connect (Windows Sockets), WSAConnect, or sendto, WSASendTo function.

For connected connectionless sockets, this function restricts the addresses from which received messages are accepted. The function only returns messages from the remote address specified in the connection. Messages from other addresses are (silently) discarded.

For overlapped sockets, WSARecv is used to post one or more buffers into which incoming data will be placed as it becomes available, after which the application-specified completion indication (invocation of the completion routine or setting of an event object) occurs. If the operation does not complete immediately, the final completion status is retrieved through the completion routine or the WSAGetOverlappedResult function.

If both lpOverlapped and lpCompletionRoutine are NULL, the socket in this function will be treated as a nonoverlapped socket.

For nonoverlapped sockets, the blocking semantics are identical to that of the standard recv function and the lpOverlapped and lpCompletionRoutine parameters are ignored. Any data that has already been received and buffered by the transport will be copied into the supplied user buffers. In the case of a blocking socket with no data currently having been received and buffered by the transport, the call will block until data is received. Winsock does not define any standard blocking time-out mechanism for this function. For protocols acting as byte-stream protocols, the stack tries to return as much data as possible subject to the supplied buffer space and the amount of received data available. However, receipt of a single byte is sufficient to unblock the caller. There is no guarantee that more than a single byte will be returned. For protocols acting as message-oriented, a full message is required to unblock the caller.

Whether or not a protocol is acting as byte stream is determined by the setting of XP1_MESSAGE_ORIENTED and XP1_PSEUDO_STREAM in its WSAPROTOCOL_INFO structure and the setting of the MSG_PARTIAL flag passed in to this function (for protocols that support it). The following table summarizes the relevant combinations, (an asterisk (*) indicates that the setting of this bit does not matter in this case).

XP1_MESSAGE

_ORIENTED

XP1_PSEUDO

_STREAM

MSG_PARTIAL

Acts as

not set

*

*

byte stream

*

set

*

byte stream

set

not set

set

byte stream

set

not set

not set

message oriented

The supplied buffers are completed the order in which they appear in the array pointed to by lpBuffers, and the buffers are packed so that no holes are created.

The array of WSABUF structures pointed to by the lpBuffers parameter is transient. If this operation completes in an overlapped manner, it is the service provider's responsibility to capture these WSABUF structures before returning from this call. This enables applications to build stack-based WSABUF arrays.

For byte stream style sockets (for example, type SOCK_STREAM), incoming data is placed into the buffers until the buffers are filled, the connection is closed, or the internally buffered data is exhausted. Regardless of whether the incoming data fills all the buffers, the completion indication occurs for overlapped sockets.

For message-oriented sockets (for example, type SOCK_DGRAM), an incoming message is placed into the supplied buffers up to the total size of the buffers supplied and the completion indication occurs for overlapped sockets. If the message is larger than the buffers supplied, the buffers are filled with the first part of the message. If MSG_PARTIAL is supported by the underlying service provider, the MSG_PARTIAL flag is set in lpFlags and subsequent receive operations will retrieve the rest of the message. If MSG_PARTIAL is not supported but the protocol is reliable, WSARecv generates the error WSAEMSGSIZE and a subsequent receive operation with a larger buffer can be used to retrieve the entire message. Otherwise (that is, the protocol is unreliable and does not support MSG_PARTIAL), the excess data is lost and WSARecv generates the error WSAEMSGSIZE.

For connection-oriented sockets, WSARecv can indicate the graceful termination of the virtual circuit in one of two ways that depend on whether the socket is byte stream or message-oriented. For byte streams, zero bytes having been read (as indicated by a zero return value to indicate success, and an lpNumberOfBytesRecvd value of zero) indicates graceful closure and that no more bytes will ever be read. For message-oriented sockets, where a zero byte message is often allowable, a failure with an error code of WSAEDISCON is used to indicate graceful closure. In any case, a return error code of WSAECONNRESET indicates an abortive close has occurred.

The lpFlags parameter can be used to influence the behavior of the function invocation beyond the options specified for the associated socket. That is, the semantics of this function are determined by the socket options and the lpFlags parameter. The following table shows the values used with the bitwise OR operator to construct the lpFlags parameter.

Value

Description

MSG_PEEK

Peeks at the incoming data. The data is copied into the buffer but is not removed from the input queue. This flag is valid only for nonoverlapped sockets.

MSG_OOB

Processes out of band (OOB) data.

MSG_PARTIAL

This flag is for message-oriented sockets only. On output, indicates that the data supplied is a portion of the message transmitted by the sender. Remaining portions of the message will be supplied in subsequent receive operations. A subsequent receive operation with MSG_PARTIAL flag cleared indicates end of sender's message.

The MSG_PARTIAL flag is not supported by the default Windows Embedded Compact provider. For message-oriented sockets, the MSG_PARTIAL bit is set in the lpFlags parameter if a partial message is received. If a complete message is received, MSG_PARTIAL is cleared in lpFlags. In the case of delayed completion, the value pointed to by lpFlags is not updated. When completion has been indicated, the application should call WSAGetOverlappedResult and examine the flags indicated by the lpdwFlags parameter.

Overlapped Socket I/O

Note

For Windows Embedded Compact, avoid specifying completion routines for overlapped I/O operations. Because Windows Embedded Compact does not support asynchronous procedure calls (APCs), which occur in the calling thread, the OS has to spin a thread for each call that specifies a completion routine. With one thread create per function call, using completion routines with overlapped I/O can quickly become very memory-consuming. Using events is recommended instead.

If an overlapped operation completes immediately, WSARecv returns a value of zero and the lpNumberOfBytesRecvd parameter is updated with the number of bytes received and the flag bits indicated by the lpFlags parameter are also updated. If the overlapped operation is successfully initiated and will complete later, WSARecv returns SOCKET_ERROR and indicates error code WSA_IO_PENDING. In this case, lpNumberOfBytesRecvd and lpFlags are not updated. When the overlapped operation completes, the amount of data transferred is indicated either through the cbTransferred parameter in the completion routine (if specified) or through the lpcbTransfer parameter in WSAGetOverlappedResult. Flag values are obtained by examining the lpdwFlags parameter of WSAGetOverlappedResult.

The WSARecv function can be called from within the completion routine of a previous WSARecv, WSARecvFrom, WSASend, or WSASendTo function. For a given socket, I/O completion routines will not be nested. This permits time-sensitive data transmissions to occur entirely within a pre-emptive context.

The lpOverlapped parameter must be valid for the duration of the overlapped operation. If multiple I/O operations are simultaneously outstanding, each must reference a separate WSAOVERLAPPED structure.

If the lpCompletionRoutine parameter is NULL, the hEvent parameter of lpOverlapped is signaled when the overlapped operation completes if it contains a valid event object handle. An application can use the WSAGetOverlappedResult function to wait or poll on the event object.

If lpCompletionRoutine is not NULL, the hEvent parameter is ignored and can be used by the application to pass context information to the completion routine. A caller that passes a non-NULL lpCompletionRoutine and later calls WSAGetOverlappedResult for the same overlapped I/O request may not set the fWait parameter for that invocation of WSAGetOverlappedResult to TRUE. In this case, the usage of the hEvent parameter is undefined and attempting to wait on the hEvent parameter would produce unpredictable results.

The transport providers allow an application to invoke send and receive operations from within the context of the socket I/O completion routine and guarantee that for a given socket, I/O completion routines will not be nested. This permits time-sensitive data transmissions to occur entirely within a pre-emptive context.

The following syntax shows the prototype of the completion routine.

void CALLBACK CompletionRoutine(
  IN DWORD dwError, 
  IN DWORD cbTransferred, 
  IN LPWSAOVERLAPPED lpOverlapped, 
  IN DWORD dwFlags
);

CompletionRoutine is a placeholder for an application-defined or library-defined function name. The dwError parameter specifies the completion status for the overlapped operation as indicated by lpOverlapped. The cbTransferred parameter specifies the number of bytes received. The dwFlags parameter contains information that would have appeared in lpFlags if the receive operation had completed immediately. This function does not return a value.

Returning from this function allows invocation of another pending completion routine for this socket.

Requirements

Header

winsock2.h

Library

Ws2.lib

See Also

Reference

Windows-Specific Extension Functions