IOleComponentUIManager.OnUIEventProgress Method
Requests the display of a progress indicator during a long-term operation.
Namespace: Microsoft.VisualStudio.Shell.Interop
Assembly: Microsoft.VisualStudio.Shell.Interop (in Microsoft.VisualStudio.Shell.Interop.dll)
Syntax
'Declaración
Function OnUIEventProgress ( _
<OutAttribute> ByRef pdwCookie As UInteger, _
fInProgress As Integer, _
pwszLabel As String, _
nComplete As UInteger, _
nTotal As UInteger _
) As Integer
'Uso
Dim instance As IOleComponentUIManager
Dim pdwCookie As UInteger
Dim fInProgress As Integer
Dim pwszLabel As String
Dim nComplete As UInteger
Dim nTotal As UInteger
Dim returnValue As Integer
returnValue = instance.OnUIEventProgress(pdwCookie, _
fInProgress, pwszLabel, nComplete, _
nTotal)
int OnUIEventProgress(
out uint pdwCookie,
int fInProgress,
string pwszLabel,
uint nComplete,
uint nTotal
)
int OnUIEventProgress(
[InAttribute] [OutAttribute] unsigned int% pdwCookie,
[InAttribute] int fInProgress,
[InAttribute] String^ pwszLabel,
[InAttribute] unsigned int nComplete,
[InAttribute] unsigned int nTotal
)
abstract OnUIEventProgress :
pdwCookie:uint32 byref *
fInProgress:int *
pwszLabel:string *
nComplete:uint32 *
nTotal:uint32 -> int
function OnUIEventProgress(
pdwCookie : uint,
fInProgress : int,
pwszLabel : String,
nComplete : uint,
nTotal : uint
) : int
Parameters
- pdwCookie
Type: System.UInt32%
[in] Identifies a progress indicator. Setting pdwCookie to zero indicates that the SOleComponentUIManager service should start a new progress indicator. If pdwCookie is not set to zero, the service should display the current progress indicator.
- fInProgress
Type: System.Int32
[in] Set to true to start or continue display of a progress indicator and false to cancel the progress display.
- pwszLabel
Type: System.String
[in] Points to the label that explains the purpose of the progress indicator. If pswzLabel is set to null on subsequent calls to update the progress of an on-going progress indicator, the previous value of the label is used.
- nComplete
Type: System.UInt32
[in] Specifies the time that has already passed for the operation.
- nTotal
Type: System.UInt32
[in] Specifies the total duration of the operation.
Return Value
Type: System.Int32
If the method succeeds, it returns S_OK. If it fails, it returns an error code.
Remarks
COM Signature
From oleipc.idl:
HRESULT IOleComponentUIManager::OnUIEventProgress(
[in][out] DWORD_PTR *pdwCookie,
[in] BOOL fInProgress,
[in] LPOLESTR pwszLabel,
[in] ULONG nComplete,
[in] ULONG nTotal
);
To start a new progress indicator, a VSPackage object calls OnUIEventProgress, setting pdwCookie to null and fInProgress to TRUE. The SOleComponentUIManager service returns a value to identify the particular progress indicator. The VSPackage object must use this value on all subsequent calls to update the progress indicator state. The VSPackage object calls OnUIEventProgress with fInProgress set to false to discontinue the progress indicator.
The SOleComponentUIManager service controls whether or not multiple progress indicators can be running simultaneously. Typically pdwCookie is set to 1 to indicate that only one progress indicator at a time is allowed.
.NET Framework Security
- Full trust for the immediate caller. This member cannot be used by partially trusted code. For more information, see Using Libraries from Partially Trusted Code.
See Also
Reference
IOleComponentUIManager Interface