Compartir a través de


IsAsyncMoniker

A version of this page is also available for

Windows Embedded CE 6.0 R3

4/8/2010

This function tests to determine whether a moniker supports asynchronous binding.

Syntax

HRESULT IsAsyncMoniker(
  IMoniker* pmk
);

Parameters

  • pmk
    [in] Address of the IMoniker interface of the moniker to be tested.

Return Value

This function returns one of the values shown in the following table.

Value Description

E_INVALIDARG

The pmk parameter is invalid.

S_FALSE

The specified moniker is not asynchronous.

S_OK

The specified moniker is asynchronous.

Remarks

A moniker implementation indicates that it is asynchronous by supporting the IAsyncMoniker interface, an empty interface that is just an implementation of IUnknown. The IsAsyncMoniker function tests for support of IAsyncMoniker and also handles composite monikers correctly.

Requirements

Header urlmon.h, urlmon.idl
Library urlmon.lib
Windows Embedded CE Windows CE .NET 4.0 and later
Windows Mobile Windows Mobile Version 5.0 and later