Compartir a través de


CIM_NetworkPort class

Represents network communications hardware such as a physical connector and the setup or operation of the network CPUs at the lowest layers of a network stack.

Important  The DMTF (Distributed Management Task Force) CIM (Common Information Model) classes are the parent classes upon which WMI classes are built. WMI currently supports only the CIM 2.x version schemas.

The following syntax is simplified from Managed Object Format (MOF) code and includes all inherited properties.

Syntax

class CIM_NetworkPort : CIM_LogicalPort
{
  string       Caption;
  string       Description;
  string       ElementName;
  string       InstanceId;
  datetime REF InstallDate;
  string       Name;
  uint16       OperationalStatus;
  string       StatusDescriptions;
  string       Status;
  uint16       HealthState;
  uint16       CommunicationStatus;
  uint16       DetailedStatus;
  uint16       OperatingStatus;
  uint16       PrimaryStatus;
  unit16       AdditionalAvailability;
  uint16       Availability;
  uint32       ConfigManagerErrorCode;
  boolean      ConfigManagerUserConfig;
  string       CreationClassName;
  string       DeviceID;
  boolean      ErrorCleared;
  string       ErrorDescription;
  string       IdentifyingDescriptions[1];
  uint32       LastErrorCode;
  uint64       MaxQuiesceTime;
  uint64       OtherIdentifyingInfo;
  string       PNPDeviceID;
  uint16       PowerManagementCapabilities[];
  boolean      PowerManagementSupported;
  uint16       StatusInfo;
  uint64       PowerOnHours;
  string       SystemCreationClassName;
  string       SystemName;
  uint64       TotalPowerOnHours;
  uint64       Speed;
  uint64       MaxSpeed;
  uint64       RequestedSpeed;
  uint16       UsageRestriction;
  uint16       PortType;
  string       OtherPortType;
  string       OtherNetworkPortType;
  uint16       PortNumber;
  uint16       LinkTechnology;
  string       OtherLinkTechnology;
  string       PermanentAddress;
  string       NetworkAddresses[];
  boolean      FullDuplex;
  boolean      AutoSense;
  uint64       SupportedMaximumTransmissionUnit;
  uint64       ActiveMaximumTransmissionUnit;
};

Members

The CIM_NetworkPort class has these types of members:

  • Methods
  • Properties

Methods

The CIM_NetworkPort class has these methods.

Method Description
Reset

Requests a reset of the logical device. Not implemented by WMI. This property inherits from CIM_LogicalDevice.

SetPowerState

Defines the desired power state for a logical device and when a device should be put into that state. Not implemented by WMI. This property inherits from CIM_LogicalDevice.

 

Properties

The CIM_NetworkPort class has these properties.

ActiveMaximumTransmissionUnit

Data type: uint64

Access type: Read-only

Qualifiers: Units ( "Bytes" )

The active or negotiated maximum transmission unit (MTU) that can be supported.

AdditionalAvailability

Data type: unit16

Access type: Write-only

Additional availability and status of the Device, beyond that specified in the Availability property. The Availability property denotes the primary status and availability of the Device. In some cases, this will not be sufficient to denote the complete status of the Device. In those cases, the AdditionalAvailability property can be used to provide further information. For example, a Device's primary Availability may be Off line (value=8), but it may also be in a low power state (AdditonalAvailability value=14), or the Device could be running Diagnostics (AdditionalAvailability value=5, In Test).

This property inherits from CIM_LogicalDevice.

Other (1)

Unknown (2)

Running/Full Power (3)

Warning (4)

In Test (5)

Not Applicable (6)

Power Off (7)

Off Line (8)

Off Duty (9)

Degraded (10)

Not Installed (11)

Install Error (12)

Power Save - Unknown (13)

Power Save - Low Power Mode (14)

Power Save - Standby (15)

Power Cycle (16)

Power Save - Warning (17)

Paused (18)

Not Ready (19)

Not Configured (20)

Quiesce (21)

AutoSense

Data type: boolean

Access type: Read-only

A Boolean that indicates whether the network port is capable of automatically determining the speed or other communications characteristics of the attached network media.

Availability

Data type: uint16

Access type: Read-only

Availability and status of the device. This property inherits from CIM_LogicalDevice.

Value Meaning
Other 1 (0x1)
Unknown 2 (0x2)
Running/Full Power 3 (0x3)
Warning 4 (0x4)
In Test 5 (0x5)
Not Applicable 6 (0x6)
Power Off 7 (0x7)
Off Line 8 (0x8)
Off Duty 9 (0x9)
Degraded 10 (0xA)
Not Installed 11 (0xB)
Install Error 12 (0xC)
Power Save - Unknown 13 (0xD)

The device is known to be in a power save mode, but its exact status is unknown.

Power Save - Low Power Mode 14 (0xE)

The device is in a power save state but still functioning, and may exhibit degraded performance.

Power Save - Standby 15 (0xF)

The device is not functioning but could be brought to full power quickly.

Power Cycle 16 (0x10)
Power Save - Warning 17 (0x11)

The device is in a warning state, though also in a power save mode.

 

Caption

Data type: string

Access type: Read-only

Qualifiers: MaxLen ( 64)

A short textual description of the object. This property inherits from CIM_ManagedElement.

CommunicationStatus

Data type: uint16

Access type: Write-only

Indicates the ability of the instrumentation to communicate with the underlying ManagedElement. This property inherits from CIM_ManagedSystemElement.

Value Meaning
Not Available 0

the implementation (provider) is capable of returning a value for this property, but not ever for this particular piece of hardware/software or the property is intentionally not used because it adds no meaningful information (as in the case of a property that is intended to add additional info to another property).

No Additional Information 1

the element is functioning normally as indicated by PrimaryStatus = OK.

Stressed 2

the element is functioning, but needs attention. Examples of Stressed states are overload, overheated, and so on.

Predictive Failure 3

an element is functioning normally but a failure is predicted in the near future.

Non-Recoverable Error 4

this element is in an error condition that requires human intervention.

Supporting Entity in Error 5

this element might be OK but that another element, on which it is dependent, is in error. An example is a network service or endpoint that cannot function due to lower-layer networking problems.

DMTF Reserved ..
Vendor Reserved 0x800

 

ConfigManagerErrorCode

Data type: uint32

Access type: Read-only

Win32 Configuration Manager error code. This property inherits from CIM_LogicalDevice.

Value Meaning
0 (0x0)

Device is working properly.

1 (0x1)

Device is not configured correctly.

2 (0x2)

Windows cannot load the driver for this device.

3 (0x3)

Driver for this device might be corrupted, or the system may be low on memory or other resources.

4 (0x4)

Device is not working properly. One of its drivers or the registry might be corrupted.

5 (0x5)

Driver for the device requires a resource that Windows cannot manage.

6 (0x6)

Boot configuration for the device conflicts with other devices.

7 (0x7)

Cannot filter.

8 (0x8)

Driver loader for the device is missing.

9 (0x9)

Device is not working properly; the controlling firmware is incorrectly reporting the resources for the device.

10 (0xA)

Device cannot start.

11 (0xB)

Device failed.

12 (0xC)

Device cannot find enough free resources to use.

13 (0xD)

Windows cannot verify the device's resources.

14 (0xE)

Device cannot work properly until the computer is restarted.

15 (0xF)

Device is not working properly due to a possible re-enumeration problem.

16 (0x10)

Windows cannot identify all of the resources that the device uses.

17 (0x11)

Device is requesting an unknown resource type.

18 (0x12)

Device drivers must be reinstalled.

19 (0x13)

Failure using the VxD loader.

20 (0x14)

Registry might be corrupted.

21 (0x15)

System failure. If changing the device driver is ineffective, see the hardware documentation. Windows is removing the device.

22 (0x16)

Device is disabled.

23 (0x17)

System failure. If changing the device driver is ineffective, see the hardware documentation.

24 (0x18)

Device is not present, not working properly, or does not have all of its drivers installed.

25 (0x19)

Windows is still setting up the device.

26 (0x1A)

Windows is still setting up the device.

27 (0x1B)

Device does not have valid log configuration.

28 (0x1C)

Device drivers are not installed.

29 (0x1D)

Device is disabled; the device firmware did not provide the required resources.

30 (0x1E)

Device is using an IRQ resource that another device is using.

31 (0x1F)

Device is not working properly; Windows cannot load the required device drivers.

 

ConfigManagerUserConfig

Data type: boolean

Access type: Read-only

If TRUE, the device is using a user-defined configuration. This property inherits from CIM_LogicalDevice.

CreationClassName

Data type: string

Access type: Read-only

Name of the class or subclass used in the creation of an instance. When used with other key properties of the class, this property allows all instances of the class and its subclasses to be uniquely identified. This property inherits from CIM_LogicalDevice.

Description

Data type: string

Access type: Read-only

A textual description of the object. This property inherits from CIM_ManagedElement.

DetailedStatus

Data type: uint16

Access type: Write-only

Compliments PrimaryStatus with additional status detail. Detailed status is used to expand upon the PrimaryStatus of the element. This property inherits from CIM_ManagedSystemElement.

Value Meaning
Not Available 0

he implementation (provider) is capable of returning a value for this property, but not ever for this particular piece of hardware/software or the property is intentionally not used because it adds no meaningful information (as in the case of a property that is intended to add additional info to another property).

No Additional Information 1

the element is functioning normally as indicated by PrimaryStatus = OK.

Stressed 2

Stressed\" indicates that the element is functioning, but needs attention. Examples of Stressed states are overload, overheated, and so on.

Predictive Failure 3

indicates that an element is functioning normally but a failure is predicted in the near future.

Non-Recoverable Error 4

indicates that this element is in an error condition that requires human intervention.

Supporting Entity in Error 5

this element might be OK but that another element, on which it is dependent, is in error. An example is a network service or endpoint that cannot function due to lower-layer networking problems.

DMTF Reserved ...
Vendor Reserved 0x800

 

DeviceID

Data type: string

Access type: Read-only

Address or other identifying information to uniquely name the logical device. This property inherits from CIM_LogicalDevice.

ElementName

Data type: string

Access type: Read-only

A user-friendly name for the object. This property enables each instance to define a display name in addition to its key properties, identity data, and description information. Be aware that the Name property of ManagedSystemElement is also defined as a display name. However, it is often subclassed to be a Key. The same property can convey both identity and a user-friendly name, without inconsistencies. Where Name exists and is not a Key (such as for instances of LogicalDevice), the same information can be present in both the Name and ElementName properties. This property inherits from CIM_ManagedElement.

ErrorCleared

Data type: boolean

Access type: Read-only

Qualifiers: Depricated

If TRUE, the error reported in the LastErrorCode property is now cleared. This property inherits from CIM_LogicalDevice.

ErrorDescription

Data type: string

Access type: Read-only

Qualifiers: Depricated

Free-form string that supplies information about the error recorded in the LastErrorCode property and corrective actions to perform. This property inherits from CIM_LogicalDevice.

FullDuplex

Data type: boolean

Access type: Read-only

Boolean that indicates that the port is operating in full duplex mode.

HealthState

Data type: uint16

Access type: Write-only

Indicates the current health of the element. This attribute expresses the health of this element but not necessarily that of its subcomponents. The possible values are 0 to 30, where 5 means the element is entirely healthy and 30 means the element is completely. This property inherits from CIM_ManagedSystemElement.

Value Meaning
Unknown 0

The implementation cannot report on HealthState at this time.

OK 5

The element is fully functional and is operating within normal operational parameters and without error.

Degraded/Warning 10

The element is in working order and all functionality is provided. However, the element is not working to the best of its abilities. For example, the element might not be operating at optimal performance or it might be reporting recoverable errors.

Minor Failure 15

All functionality is available but some might be degraded.

Major Failure 20

The element is failing. It is possible that some or all of the functionality of this component is degraded or not working.

Critical Failure 25

The element is non-functional and recovery might not be possible.

Non-recoverable Error 30

The element has completely failed, and recovery is not possible. All functionality provided by this element has been lost.

Reserved ...

The remaining values are reserved for DTMF use.

 

IdentifyingDescriptions

Data type: string array

Access type: Read-only

An array of free-form strings providing explanations and details behind the entries in the OtherIdentifyingInfo array. Note, each entry of this array is related to the entry in OtherIdentifyingInfo that is located at the same index. This property inherits from CIM_LogicalDevice.

InstallDate

Data type: datetime

Access type: Read-only

Indicates when the object was installed. Lack of a value does not indicate that the object is not installed. This property inherits from CIM_ManagedSystemElement.

InstanceId

Data type: string

Access type: Read-only

Within the scope of the instantiating Namespace, InstanceID opaquely and uniquely identifies an instance of this class. To ensure uniqueness within the NameSpace, the value of InstanceID should be constructed using the following "preferred" algorithm: OrgID:LocalID Where OrgID and LocalID are separated by a colon (:), and where OrgID must include a copyrighted, trademarked, or otherwise unique name that is owned by the business entity that is creating or defining the InstanceID or that is a registered ID assigned to the business entity by a recognized global authority. (This requirement is similar to the SchemaName_ClassName structure of Schema class names.) In addition, to ensure uniqueness, OrgID must not contain a colon (:). When using this algorithm, the first colon to appear in InstanceID must appear between OrgID and LocalID. LocalID is chosen by the business entity and should not be reused to identify different underlying (real-world) elements. If the above preferred algorithm is not used, the defining entity must assure that the resulting InstanceID is not reused across any InstanceIDs produced by this or other providers for the NameSpace of this instance. For DMTF-defined instances, the "preferred" algorithm must be used with the OrgID set to CIM. This property inherits from CIM_ManagedElement.

LastErrorCode

Data type: uint32

Access type: Read-only

Qualifiers: Depricated

Last error code reported by the logical device. This property inherits from CIM_LogicalDevice.

LinkTechnology

Data type: uint16

Access type: Read-only

An enumeration of the types of links. When set to 1 ("Other"), the related property OtherLinkTechnology contains a string description of the type of link.

Unknown (0)

Other (1)

Ethernet (2)

IB (3)

FC (4)

FDDI (5)

ATM (6)

Token Ring (7)

Frame Relay (8)

Infrared (9)

BlueTooth (10)

Wireless LAN (11)

MaxQuiesceTime

Data type: uint64

Access type: Read-only

Qualifiers: Depricated

Maximum time in milliseconds, that a Device can run in a Quiesced state. A Device's state is defined in its Availability and AdditionalAvailability properties, where Quiesced is conveyed by the value 21. What occurs at the end of the time limit is device-specific. The Device may unquiesce, may offline or take other action. A value of 0 indicates that a Device can remain quiesced indefinitely.

Note  

"The MaxQuiesceTime property has been deprecated. When evaluating the use of Quiesce, it was determine that this single property is not adequate for describing when a device will automatically exit a quiescent state. In fact, the most likely scenario for a device to exit a quiescent state was determined to be based on the number of outstanding requests queued rather than on a maximum time. This will be re-evaluated and repositioned later.

This property inherits from CIM_LogicalDevice.

MaxSpeed

Data type: uint64

Access type: Read-only

Qualifiers: Units ( "Bits per Second" )

The maximum bandwidth, in bits per second, of the port. This property inherits from CIM_LogicalPort.

Name

Data type: string

Access type: Read-only

Label by which the object is known. When subclassed, this property can be overridden to be a key property. This property inherits from CIM_ManagedSystemElement.

NetworkAddresses

Data type: string array

Access type: Read-only

Qualifiers: MaxLen ( 64)

An array of strings that indicates the network addresses for the port.

OperatingStatus

Data type: uint16

Access type: Read-only

Provides a current status value for the operational condition of the element and can be used for providing more detail with respect to the value of EnabledState. It can also provide the transitional states when an element is transitioning from one state to another, such as when an element is transitioning between EnabledState and RequestedState, as well as other transitional conditions. This property inherits from CIM_ManagedSystemElement.

Value Meaning
Unknown 0

the implementation is in general capable of returning this property, but is unable to do so at this time.

Not Available 1

the implementation (provider) is capable of returning a value for this property, but not ever for this particular piece of hardware/software or the property is intentionally not used because it adds no meaningful information (as in the case of a property that is intended to add additional info to another property).

Servicing 2

describes an element being configured, maintained, cleaned, or otherwise administered. Starting describes an element being initialized. \n\"Stopping\" describes an element being brought to an orderly stop.

Starting 3

The element is starting.

Stopping 4

The element is stopping.

Stopped 5

A a clean and orderly stop has occurred.

Aborted 6

An abrupt stop has occurred; the state and configuration of the element might need to be updated.

Dormant 7

The element is inactive or quiesced.

Completed 8

The element has completed its operation. This value should be combined with either OK, Error, or Degraded in the PrimaryStatus so that a client can tell if the complete operation Completed with OK (passed), Completed with Error (failed), or Completed with Degraded (the operation finished, but it did not complete OK or did not report an error).

Migrating 9

The element is being moved between host elements.

Emigrating 10

The element is being moved away from host element.

Immigrating 11

The element is being moved to new host element.

Snapshotting 12
Shutting Down 13

The element being brought to an abrupt stop.

In Test 14

The element is performing test functions.

Transitioning 15

The element is between states, that is, it is not fully available in either its previous state or its next state. This value should be used if other values indicating a transition to a specific state are not applicable.

In Service 16

The element is in service and operational."

DTMF Reserved ..
Vendor Reserved 0x800

 

OperationalStatus

Data type: uint16

Access type: Write-only

The current statuses of the element. This property inherits from CIM_ManagedSystemElement.

Value Meaning
Unknown 0

An unknown error has occured.

Other 1

An error other than one on this list has occured.

OK 2

The elemetn is OK.

Degraded 3

The element has been degraded.

Stressed 4

The element is functioning, but needs attention. Examples of Stressed states are overload, overheated, and so on.

Predictive Failure 5

An element is functioning nominally but predicting a failure in the near future.

Error 6

An error has occurred.

Non-Recoverable Error 7

A non-recoverable error has occurred.

Starting 8

The element is in the process of starting.

Stopping 9

The element is in the process of stopping.

Stopped 10

A clean and orderly stop has occurred.

In Service 11

An element being configured, maintained, cleaned, or otherwise administered.

No Contact 12

The monitoring system has knowledge of this element, but has never been able to establish communications with it.

Lost Communication 13

The Managed System Element is known to exist and has been contacted successfully in the past, but is currently unreachable.

Aborted 14

An abrupt stop has occurred; the state and configuration of the element might need to be updated.

Dormant 15

The element is inactive or quiesced.

Supporting Entity in Error 16

The current element might be OK, but that another element, on which it is dependent, is in error. An example is a network service or endpoint that cannot function due to lower-layer networking problems.

Completed 17

the element has completed its operation. This value should be combined with either OK, Error, or Degraded so that a client can tell if the complete operation Completed with OK (passed), Completed with Error (failed), or Completed with Degraded (the operation finished, but it did not complete OK or did not report an error)

Power Mode 18

The element has additional power model information contained in the Associated PowerManagementService association.

Relocating 19

indicates the element is being relocated. OperationalStatus replaces the Status property on ManagedSystemElement to provide a consistent approach to enumerations, to address implementation needs for an array property, and to provide a migration path from today\'s environment to the future. This change was not made earlier because it required the deprecated qualifier. Due to the widespread use of the existing Status property in management applications, it is strongly recommended that providers or instrumentation provide both the Status and OperationalStatus properties. Further, the first value of OperationalStatus should contain the primary status for the element. When instrumented, Status (because it is single-valued) should also provide the primary status of the element.

DMTF Reserved ..

Reserved for the DTMF.

Vendor Reserved 0x8000

Reserved for the vendors.

 

OtherIdentifyingInfo

Data type: uint64

Access type: Read-only

Array that captures additional data, beyond DeviceID information, that could be used to identify a LogicalDevice. One example would be to hold the Operating System's user friendly name for the Device in this property. Maximum length is 256. This property inherits from CIM_LogicalDevice.

OtherLinkTechnology

Data type: string

Access type: Read-only

A string value that describes LinkTechnology when it is set to 1, "Other".

OtherNetworkPortType

Data type: string

Access type: Read-only

Qualifiers: Depricated

Note: The use of this property is deprecated in lieu of CIM_LogicalPort.PortType.

The type of module, when PortType is set to 1 ("Other".)

OtherPortType

Data type: string

Access type: Write-only

Describes the type of module, when PortType is set to 1 ("Other"). This property inherits from CIM_LogicalPort.

PermanentAddress

Data type: string

Access type: Read-only

Qualifiers: MaxLen ( 64)

The network address that is hardcoded into a port. This hardcoded address can be changed using a firmware upgrade or a software configuration. When this change is made, the field should be updated at the same time. PermanentAddress should be left blank if no hardcoded address exists for the network adapter.

PNPDeviceID

Data type: string

Access type: Read-only

Indicates the Win32 Plug and Play device identifier of the logical device. This property inherits from CIM_LogicalDevice.

Example: "*PNP030b"

PortNumber

Data type: uint16

Access type: Read-only

Network ports are often numbered relative to either a logical module or a network element.

PortType

Data type: uint16

Access type: Write-only

Forces consistent naming of the 'type' property in subclasses and to guarantee unique enum values for all instances of NetworkPort. When set to 1 ("Other"), related property OtherPortType contains a string description of the type of port. A range of values, DMTF_Reserved, has been defined that allows subclasses to override and define their specific types of ports. This property inherits from CIM_LogicalPort.

Unknown (0)

Other (1)

Not Applicable (2)

DMTF Reserved (3..15999)

Vendor Reserved (16000..65535)

PowerManagementCapabilities

Data type: uint16 array

Access type: Read-only

Qualifiers: Depricated

Array of the specific power-related capabilities of a logical device. This property is inherited from CIM_LogicalDevice. This property inherits from CIM_LogicalDevice.

Value Meaning
Unknown 0 (0x0)
Not Supported 1 (0x1)
Disabled 2 (0x2)
Enabled 3 (0x3)

The power management features are currently enabled but the exact feature set is unknown or the information is unavailable.

Power Saving Modes Entered Automatically 4 (0x4)

The device can change its power state based on usage or other criteria.

Power State Settable 5 (0x5)

The SetPowerState method is supported. This method is found on the parent CIM_LogicalDevice class and can be implemented. For more information, see Designing Managed Object Format (MOF) Classes.

Power Cycling Supported 6 (0x6)

The SetPowerState method can be invoked with the PowerState parameter set to 5 ("Power Cycle").

Timed Power On Supported 7 (0x7)

The SetPowerState method can be invoked with the PowerStateparameter set to 5 ("Power Cycle") and Time set to a specific date and time, or interval, for power-on.

 

PowerManagementSupported

Data type: boolean

Access type: Read-only

Qualifiers: Depricated

If TRUE, the device can be power managed, that is, put into a power-save state. If FALSE, the integer value 1 ("Not Supported") should be the only entry in the PowerManagementCapabilities array.

This property does not indicate whether power management features are currently enabled, or if enabled, which features are supported. For more information, see the PowerManagementCapabilities array.

This property inherits from CIM_LogicalDevice.

PowerOnHours

Data type: uint64

Access type: Read-only

The number of consecutive hours that this Device has been powered, since its last power cycle. This property inherits from CIM_LogicalDevice.

PrimaryStatus

Data type: uint16

Access type: Write-only

provides a high level status value, intended to align with Red-Yellow-Green type representation of status. It should be used in conjunction with DetailedStatus to provide high level and detailed health status of the ManagedElement and its subcomponents. This property inherits from CIM_ManagedSystemElement.

Unknown (0)

OK (1)

Degraded (2)

Error (3)

DMTF Reserved (...)

Vendor Reserved (0x8000)

RequestedSpeed

Data type: uint64

Access type: Write-only

Qualifiers: Units ( "Bits per Second" )

The requested bandwidth, in bits per second, of the port. The actual bandwidth is reported in the Speed property. This property inherits from CIM_LogicalPort.

Speed

Data type: uint64

Access type: Read-only

Qualifiers: Units ( "Bits per Second" )

The bandwidth, in bits per second, of the port. This property inherits from CIM_LogicalPort.

Status

Data type: string

Access type: Read-only

String that indicates the current status of the object. Operational and non-operational status can be defined. Operational status can include "OK", "Degraded", and "Pred Fail". "Pred Fail" indicates that an element is functioning properly, but is predicting a failure (for example, a SMART-enabled hard disk drive).

Non-operational status can include "Error", "Starting", "Stopping", and "Service". "Service" can apply during disk mirror-resilvering, reloading a user permissions list, or other administrative work. Not all such work is online, but the managed element is neither "OK" nor in one of the other states. This property inherits from CIM_ManagedSystemElement.

Values include the following:

"OK"

"Error"

"Degraded"

"Unknown"

"Pred Fail"

"Starting"

"Stopping"

"Service"

"Stressed"

"NonRecover"

"No Contact"

"Lost Comm"

StatusDescriptions

Data type: string

Access type: Write-only

Strings describing the various OperationalStatus array values. For example, if Stopping is the value assigned to OperationalStatus, then this property may contain an explanation as to why an object is being stopped. Note that entries in this array are correlated with those at the same array index in OperationalStatus. This property inherits from CIM_ManagedSystemElement.

StatusInfo

Data type: uint16

Access type: Read-only

Qualifiers: Depricated

State of the logical device. If this property does not apply to the logical device, the value 5 ("Not Applicable") should be used. This property inherits from CIM_LogicalDevice.

Other (1 (0x1))

Unknown (2 (0x2))

Enabled (3 (0x3))

Disabled (4 (0x4))

Not Applicable (5 (0x5))

SupportedMaximumTransmissionUnit

Data type: uint64

Access type: Read-only

Qualifiers: Units ( "Bytes" )

The maximum transmission unit (MTU) that can be supported.

SystemCreationClassName

Data type: string

Access type: Read-only

Scoping system's creation class name. This property inherits from CIM_LogicalDevice.

SystemName

Data type: string

Access type: Read-only

Scoping system's name. This property inherits from CIM_LogicalDevice.

TotalPowerOnHours

Data type: uint64

Access type: Read-only

The total number of hours that this device has been powered. This property inherits from CIM_LogicalDevice.

UsageRestriction

Data type: uint16

Access type: Write-only

In some cases, a logical port might be identifiable as a front end or back end port. An example of this situation would be a storage array that might have back end ports to communicate with disk drives and front end ports to communicate with hosts. If there is no restriction on the use of the port, then the value should be set to 'not restricted'. This property inherits from CIM_LogicalPort.

Unknown (0)

Front-end only (2)

Back-end only (3)

Not restricted (4)

Requirements

Namespace

Root\CIMV2

See also

CIM_LogicalPort