MSMCAEvent_PlatformSpecificError class

The MSMCAEvent_PlatformSpecificError class indicates a Machine Check Architecture (MCA) platform-specific error. This class is available only in 64-bit Windows systems.

The following syntax is simplified from Managed Object Format (MOF) code and includes all of its inherited properties. Properties and methods are in alphabetic order, not MOF order.

Syntax

class MSMCAEvent_PlatformSpecificError : WMIEvent
{
  boolean Active;
  uint32  AdditionalErrors;
  uint32  Cpu;
  uint8   ErrorSeverity;
  string  InstanceName;
  uint8   OEM_COMPONENT_ID;
  uint64  PLATFORM_BUS_SPECIFIC_DATA;
  uint64  PLATFORM_ERROR_STATUS;
  uint64  PLATFORM_REQUESTOR_ID;
  uint64  PLATFORM_RESPONDER_ID;
  uint64  PLATFORM_TARGET_ID;
  uint8   RawRecord[];
  uint64  RecordId;
  uint32  Size;
  uint32  Type;
  uint64  VALIDATION_BITS;
  uint32  LogToEventlog;
};

Members

The MSMCAEvent_PlatformSpecificError class has these types of members:

Properties

The MSMCAEvent_PlatformSpecificError class has these properties.

Active

Data type: boolean

Access type: Read-only

TRUE, if this instance of the class is active; otherwise, FALSE.

AdditionalErrors

Data type: uint32

Access type: Read-only

Number of additional errors in the record.

Cpu

Data type: uint32

Access type: Read-only

CPU that reported the error. This property only applies to a multiprocessor system in which the first processor is assigned the number 0, the second processor is assigned the number 1, and so on.

ErrorSeverity

Data type: uint8

Access type: Read-only

Severity level of the error reported.

Value Meaning
0
Recoverable
1
Fatal
2
Correctable

InstanceName

Data type: string

Access type: Read-only

Qualifiers: Key

Unique identifier of this instance of the class.

LogToEventlog

Data type: uint32

Access type: Read-only

If 0 (zero) then this event is not logged to the system event log.

OEM_COMPONENT_ID

Data type: uint8

Access type: Read-only

Unique identifier of the component that reports the error.

PLATFORM_BUS_SPECIFIC_DATA

Data type: uint64

Access type: Read-only

OEM-specific, bus-dependent data.

For more information about using uint64 values in scripts, see Scripting in WMI.

PLATFORM_ERROR_STATUS

Data type: uint64

Access type: Read-only

Generic platform error status.

For more information about using uint64 values in scripts, see Scripting in WMI.

PLATFORM_REQUESTOR_ID

Data type: uint64

Access type: Read-only

Requestor identifier at the time of the event.

For more information about using uint64 values in scripts, see Scripting in WMI.

PLATFORM_RESPONDER_ID

Data type: uint64

Access type: Read-only

Responder identifier at the time of the event.

For more information about using uint64 values in scripts, see Scripting in WMI.

PLATFORM_TARGET_ID

Data type: uint64

Access type: Read-only

Target identifier at the time of the event.

For more information about using uint64 values in scripts, see Scripting in WMI.

RawRecord

Data type: uint8 array

Access type: Read-only

Array of bytes that contains the raw error record as presented to Windows by the system abstraction layer (SAL). The number of elements in the array is specified by the Size property.

RecordId

Data type: uint64

Access type: Read-only

Record identifier of the error record for this error.

For more information about using uint64 values in scripts, see Scripting in WMI.

Size

Data type: uint32

Access type: Read-only

Size of the raw error record.

Type

Data type: uint32

Access type: Read-only

Type of event log message. These messages correspond to the event log message codes used to insert event log messages by the Windows event log consumer provider when it receives one of the events.

VALIDATION_BITS

Data type: uint64

Access type: Read-only

Validation bits used to indicate the validity of the subsequent fields.

Value Meaning
1 0x1
PLATFORM_ERROR_STATUS is valid.
2 0x2
PLATFORM_ERROR_REQUESTOR_ID is valid.
4 0x4
PLATFORM_ERROR_RESPONDER_ID is valid.
8 0x8
PLATFORM_ERROR_TARGET_ID is valid.
16 0x10
PLATFORM_ERROR_SPECIFIC_DATA is valid.
32 0x20
PLATFORM_ERROR_OEM_ID is valid.
64 0x40
PLATFORM_ERROR_OEM_DATA_STRUCT is valid.
128 0x80
PLATFORM_ERROR_OEM_DEVICE_PATH is valid.

For more information about using uint64 values in scripts, see Scripting in WMI.

Remarks

The MSMCAEvent_PlatformSpecificError class is derived from WMIEvent.

Requirements

Requirement Value
Minimum supported client
Windows XP
Minimum supported server
Windows Server 2003
Namespace
Root\wmi
MOF
Wmicore.mof
DLL
Wmiprov.dll

See also

MSMCA Classes

WMIEvent