MSMCAEvent_PlatformSpecificError class
The MSMCAEvent_PlatformSpecificError class indicates a Machine Check Architecture (MCA) platform-specific error. This class is available only in 64-bit Windows systems.
The following syntax is simplified from Managed Object Format (MOF) code and includes all of its inherited properties. Properties and methods are in alphabetic order, not MOF order.
Syntax
class MSMCAEvent_PlatformSpecificError : WMIEvent
{
boolean Active;
uint32 AdditionalErrors;
uint32 Cpu;
uint8 ErrorSeverity;
string InstanceName;
uint8 OEM_COMPONENT_ID;
uint64 PLATFORM_BUS_SPECIFIC_DATA;
uint64 PLATFORM_ERROR_STATUS;
uint64 PLATFORM_REQUESTOR_ID;
uint64 PLATFORM_RESPONDER_ID;
uint64 PLATFORM_TARGET_ID;
uint8 RawRecord[];
uint64 RecordId;
uint32 Size;
uint32 Type;
uint64 VALIDATION_BITS;
uint32 LogToEventlog;
};
Members
The MSMCAEvent_PlatformSpecificError class has these types of members:
Properties
The MSMCAEvent_PlatformSpecificError class has these properties.
-
Active
-
-
Data type: boolean
-
Access type: Read-only
TRUE, if this instance of the class is active; otherwise, FALSE.
-
-
AdditionalErrors
-
-
Data type: uint32
-
Access type: Read-only
Number of additional errors in the record.
-
-
Cpu
-
-
Data type: uint32
-
Access type: Read-only
CPU that reported the error. This property only applies to a multiprocessor system in which the first processor is assigned the number 0, the second processor is assigned the number 1, and so on.
-
-
ErrorSeverity
-
-
Data type: uint8
-
Access type: Read-only
Severity level of the error reported.
Value Meaning - 0
Recoverable - 1
Fatal - 2
Correctable -
-
InstanceName
-
-
Data type: string
-
Access type: Read-only
-
Qualifiers: Key
Unique identifier of this instance of the class.
-
-
LogToEventlog
-
-
Data type: uint32
-
Access type: Read-only
If 0 (zero) then this event is not logged to the system event log.
-
-
OEM_COMPONENT_ID
-
-
Data type: uint8
-
Access type: Read-only
Unique identifier of the component that reports the error.
-
-
PLATFORM_BUS_SPECIFIC_DATA
-
-
Data type: uint64
-
Access type: Read-only
OEM-specific, bus-dependent data.
For more information about using uint64 values in scripts, see Scripting in WMI.
-
-
PLATFORM_ERROR_STATUS
-
-
Data type: uint64
-
Access type: Read-only
Generic platform error status.
For more information about using uint64 values in scripts, see Scripting in WMI.
-
-
PLATFORM_REQUESTOR_ID
-
-
Data type: uint64
-
Access type: Read-only
Requestor identifier at the time of the event.
For more information about using uint64 values in scripts, see Scripting in WMI.
-
-
PLATFORM_RESPONDER_ID
-
-
Data type: uint64
-
Access type: Read-only
Responder identifier at the time of the event.
For more information about using uint64 values in scripts, see Scripting in WMI.
-
-
PLATFORM_TARGET_ID
-
-
Data type: uint64
-
Access type: Read-only
Target identifier at the time of the event.
For more information about using uint64 values in scripts, see Scripting in WMI.
-
-
RawRecord
-
-
Data type: uint8 array
-
Access type: Read-only
Array of bytes that contains the raw error record as presented to Windows by the system abstraction layer (SAL). The number of elements in the array is specified by the Size property.
-
-
RecordId
-
-
Data type: uint64
-
Access type: Read-only
Record identifier of the error record for this error.
For more information about using uint64 values in scripts, see Scripting in WMI.
-
-
Size
-
-
Data type: uint32
-
Access type: Read-only
Size of the raw error record.
-
-
Type
-
-
Data type: uint32
-
Access type: Read-only
Type of event log message. These messages correspond to the event log message codes used to insert event log messages by the Windows event log consumer provider when it receives one of the events.
-
-
VALIDATION_BITS
-
-
Data type: uint64
-
Access type: Read-only
Validation bits used to indicate the validity of the subsequent fields.
Value Meaning - 1 0x1
PLATFORM_ERROR_STATUS is valid. - 2 0x2
PLATFORM_ERROR_REQUESTOR_ID is valid. - 4 0x4
PLATFORM_ERROR_RESPONDER_ID is valid. - 8 0x8
PLATFORM_ERROR_TARGET_ID is valid. - 16 0x10
PLATFORM_ERROR_SPECIFIC_DATA is valid. - 32 0x20
PLATFORM_ERROR_OEM_ID is valid. - 64 0x40
PLATFORM_ERROR_OEM_DATA_STRUCT is valid. - 128 0x80
PLATFORM_ERROR_OEM_DEVICE_PATH is valid. For more information about using uint64 values in scripts, see Scripting in WMI.
-
Remarks
The MSMCAEvent_PlatformSpecificError class is derived from WMIEvent.
Requirements
Requirement | Value |
---|---|
Minimum supported client |
Windows XP |
Minimum supported server |
Windows Server 2003 |
Namespace |
Root\wmi |
MOF |
|
DLL |
|