Win32_TSPermissionsSetting class

The Win32_TSPermissionsSetting WMI class includes a method to add new accounts to the terminal and a method to restore the default permissions to a terminal.

The following syntax is simplified from MOF code and includes all defined and inherited properties, in alphabetical order. For reference information on methods, see the table of methods later in this topic.

Syntax

[dynamic, provider("Win32_WIN32_TSPERMISSIONSSETTING_Prov"), ClassContext("local|hkey_local_machine\\SYSTEM\\CurrentControlSet\\Control\\TerminalServer\\WinStations"), AMENDMENT]
class Win32_TSPermissionsSetting : Win32_TerminalSetting
{
  string   Caption;
  string   Description;
  datetime InstallDate;
  string   Name;
  string   Status;
  string   TerminalName;
  uint32   DenyAdminPermissionForCustomization;
  uint32   PolicySourceDenyAdminPermissionForCustomization;
  string   StringSecurityDescriptor;
};

Members

The Win32_TSPermissionsSetting class has these types of members:

Methods

The Win32_TSPermissionsSetting class has these methods.

Method Description
AddAccount Adds an account to the terminal with the permission set specified in the value of the PermissionPreSet parameter.
RestoreDefaults Restores the default permission set values for the terminal.

Properties

The Win32_TSPermissionsSetting class has these properties.

Caption

Data type: string

Access type: Read-only

Qualifiers: MaxLen (64)

Short description (one-line string) of the object.

This property is inherited from CIM_ManagedSystemElement.

DenyAdminPermissionForCustomization

Data type: uint32

Access type: Read-only

Specifies whether local administrator has permission to customize.

Description

Data type: string

Access type: Read-only

Description of the object.

This property is inherited from CIM_ManagedSystemElement.

InstallDate

Data type: datetime

Access type: Read-only

Qualifiers: Mappingstrings ("MIF.DMTF|ComponentID|001.5")

The date the object was installed. A lack of a value does not indicate that the object is not installed.

This property is inherited from CIM_ManagedSystemElement.

Name

Data type: string

Access type: Read-only

The name of the object.

This property is inherited from CIM_ManagedSystemElement.

PolicySourceDenyAdminPermissionForCustomization

Data type: uint32

Access type: Read-only

Indicates whether the MinEncryptionLevel property is configured by the server, group policy, or by default.

0

Server

1

Group policy

Status

Data type: string

Access type: Read-only

Qualifiers: MaxLen (10)

Current status of the object. Various operational and nonoperational statuses can be defined. Operational statuses include: "OK", "Degraded", and "Pred Fail" (an element, such as a SMART-enabled hard disk drive, may be functioning properly but predicting a failure in the near future). Nonoperational statuses include: "Error", "Starting", "Stopping", and "Service". The latter, "Service", could apply during mirror-resilvering of a disk, reload of a user permissions list, or other administrative work. Not all such work is on-line, yet the managed element is neither "OK" nor in one of the other states.

This property is inherited from CIM_ManagedSystemElement.

("OK")

("Error")

("Degraded")

("Unknown")

("Pred Fail")

("Starting")

("Stopping")

("Service")

StringSecurityDescriptor

Data type: string

Access type: Read/write

Security descriptor associated with the terminal in binary byte array format.

TerminalName

Data type: string

Access type: Read-only

The name of the terminal.

This property is inherited from Win32_TerminalSetting.

Remarks

To connect to the \root\CIMV2\TerminalServices namespace, the authentication level must include packet privacy. For C/C++ calls, this is an authentication level of RPC_C_AUTHN_LEVEL_PKT_PRIVACY. For Visual Basic and scripting calls, this is an authentication level of WbemAuthenticationLevelPktPrivacy or "pktPrivacy", with a value of 6. The following Visual Basic Scripting Edition (VBScript) example shows how to connect to a remote computer with packet privacy.

strComputer = "RemoteServer1" 
Set objServices = GetObject( _
    "winmgmts:{authenticationLevel=pktPrivacy}!Root/CIMv2/TerminalServices")

Managed Object Format (MOF) files contain the definitions for Windows Management Instrumentation (WMI) classes. MOF files are not installed as part of the Microsoft Windows Software Development Kit (SDK). They are installed on the server when you add the associated role by using the Server Manager. For more information about MOF files, see Managed Object Format (MOF).

Requirements

Requirement Value
Minimum supported client
Windows Vista
Minimum supported server
Windows Server 2008
Namespace
Root\CIMv2\TerminalServices
MOF
TSCfgWmi.mof
DLL
TSCfgWmi.dll

See also

Win32_TerminalSetting