Win32_TSDeploymentSettings class
Defines the default settings that the RemoteApp Manager uses when creating Remote Desktop Protocol (RDP) files. These settings do not affect any published applications or desktops.
Syntax
class Win32_TSDeploymentSettings : CIM_LogicalElement
{
string Caption;
string Description;
datetime InstallDate;
string Name;
string Status;
sint32 Port;
string FarmName;
sint32 GatewayUsage;
string GatewayName;
sint32 GatewayAuthMode;
boolean GatewayUseCachedCreds;
boolean RequireServerAuth;
sint32 ColorBitDepth;
boolean AllowFontSmoothing;
boolean UseMultimon;
sint32 RedirectionOptions;
boolean HasCertificate;
uint8 CertificateHash[];
string CertificateIssuedTo;
string CertificateIssuedBy;
string CertificateExpiresOn;
string CustomRDPSettings;
string DeploymentRDPSettings;
};
Members
The Win32_TSDeploymentSettings class has these types of members:
Properties
The Win32_TSDeploymentSettings class has these properties.
-
AllowFontSmoothing
-
-
Data type: boolean
-
Access type: Read/write
Indicates whether to allow font smoothing.
-
-
Caption
-
-
Data type: string
-
Access type: Read-only
-
Qualifiers: MaxLen (64)
Short description (one-line string) of the object.
This property is inherited from CIM_ManagedSystemElement.
-
-
CertificateExpiresOn
-
-
Data type: string
-
Access type: Read/write
The date that the certificate expires on. This value is stored as a 64-bit FILETIME format.
-
-
CertificateHash
-
-
Data type: uint8 array
-
Access type: Read/write
The thumbprint of the certificate that is used to sign RDP files.
-
-
CertificateIssuedBy
-
-
Data type: string
-
Access type: Read/write
Specifies who the certificate is issued by.
-
-
CertificateIssuedTo
-
-
Data type: string
-
Access type: Read/write
Specifies who the certificate is issued to.
-
-
ColorBitDepth
-
-
Data type: sint32
-
Access type: Read/write
The color bit depth of the display. Possible values are 4, 8, 15, 16, 24, and 32.
-
-
CustomRDPSettings
-
-
Data type: string
-
Access type: Read/write
The contents of the RDP file that correspond to the Custom RDP Settings in RemoteApp Manager.
-
-
DeploymentRDPSettings
-
-
Data type: string
-
Access type: Read/write
The contents of the RDP file that correspond to the deployment settings in RemoteApp Manager. If this value is set, the RDP deployment settings supersede the default settings in this class. For example, if you set the GatewayAuthMode property in this class, and set the DeploymentRDPSettings property, the GatewayAuthMode property from this class will be ignored and the GatewayAuthMode value from the DeploymentRDPSettings will be used.
-
-
Description
-
-
Data type: string
-
Access type: Read-only
Description of the object.
This property is inherited from CIM_ManagedSystemElement.
-
-
FarmName
-
-
Data type: string
-
Access type: Read/write
The name of the RD Session Host server, or the fully qualified domain name (FQDN) of the RD Session Host server farm.
-
-
GatewayAuthMode
-
-
Data type: sint32
-
Access type: Read/write
The RD Gateway authentication method. The following values are possible.
-
-
0
-
Password
-
1
-
Smart card
-
4
-
Allow user to select during connection.
GatewayName
-
Data type: string
-
Access type: Read/write
The name of the RD Gateway server to use.
GatewayUsage
-
Data type: sint32
-
Access type: Read/write
Indicates whether to use an RD Gateway server to connect to the target RD Session Host server across a firewall. The following values are possible.
0
Do not use an RD Gateway server.
1
Use an RD Gateway server. Bypass the RD Gateway server for local addresses.
2
Use an RD Gateway server.
3
Automatically detect RD Gateway server settings.
GatewayUseCachedCreds
-
Data type: boolean
-
Access type: Read/write
When possible, use the same user credentials for the RD Gateway server and the RD Session Host server.
HasCertificate
-
Data type: boolean
-
Access type: Read/write
Indicates whether to use a certificate to sign the RDP files.
InstallDate
-
Data type: datetime
-
Access type: Read-only
-
Qualifiers: Mappingstrings ("MIF.DMTF|ComponentID|001.5")
The date the object was installed. A lack of a value does not indicate that the object is not installed.
This property is inherited from CIM_ManagedSystemElement.
Name
-
Data type: string
-
Access type: Read-only
The name of the object.
This property is inherited from CIM_ManagedSystemElement.
Port
-
Data type: sint32
-
Access type: Read/write
The RDP port to use.
RedirectionOptions
-
Data type: sint32
-
Access type: Read/write
Specifies the device and resource redirection options for RemoteApp connections. Flags for RedirectionOptions can be combined. The following values are possible.
0
No device or resource redirection.
1
Redirect disk drives.
2
Redirect printers.
4
Redirect the Clipboard.
8
Redirect supported Plug and Play devices.
16
Redirect smart cards.
32
Redirect audio.
64
Redirect serial ports.
RequireServerAuth
-
Data type: boolean
-
Access type: Read/write
Indicates whether to require server authentication.
Status
-
Data type: string
-
Access type: Read-only
-
Qualifiers: MaxLen (10)
Current status of the object. Various operational and nonoperational statuses can be defined. Operational statuses include: "OK", "Degraded", and "Pred Fail" (an element, such as a SMART-enabled hard disk drive, may be functioning properly but predicting a failure in the near future). Nonoperational statuses include: "Error", "Starting", "Stopping", and "Service". The latter, "Service", could apply during mirror-resilvering of a disk, reload of a user permissions list, or other administrative work. Not all such work is on-line, yet the managed element is neither "OK" nor in one of the other states.
This property is inherited from CIM_ManagedSystemElement.
("OK")
("Error")
("Degraded")
("Unknown")
("Pred Fail")
("Starting")
("Stopping")
("Service")
UseMultimon
-
Data type: boolean
-
Access type: Read/write
Indicates if multiple monitors are enabled for the desktop.
Remarks
You must be a member of the Administrators group to set properties by using this class.
If RequireServerAuth is set to TRUE, consider the following:
- If the RemoteApp program is for intranet use, and all client computers are running either Windows Server 2008 or Windows Vista, you do not have to configure the RD Session Host server to use an SSL certificate. In this case, Network Level Authentication is used.
- You must specify the FQDN of the server or farm for the value of the FarmName property.
To connect to the "CIMV2\TerminalServices" namespace, the authentication level must include packet privacy. For C/C++ calls, this is an authentication level of RPC_C_AUTHN_LEVEL_PKT_PRIVACY, which can be set by using the CoSetProxyBlanket COM function. For Visual Basic and scripting calls, this is an authentication level of WbemAuthenticationLevelPktPrivacy or "pktPrivacy", with a value of 6. The following Visual Basic Scripting Edition (VBScript) example shows how to connect to a remote computer with packet privacy.
strComputer = "RemoteServer1"
Set objServices = GetObject( _
"winmgmts:{authenticationLevel=pktPrivacy}!Root/CIMv2/TerminalServices")
Managed Object Format (MOF) files contain the definitions for Windows Management Instrumentation (WMI) classes. They are installed on the computer when you add the associated role. For more information about MOF files, see Managed Object Format (MOF).
Requirements
Requirement | Value |
---|---|
Minimum supported client |
None supported |
Minimum supported server |
Windows Server 2008 |
Namespace |
Root\CIMv2\TerminalServices |
MOF |
|
DLL |
|