DiskQuotaControl.FindUser method
Finds a user's entry, by name, in the volume's quota file.
Syntax
DiskQuotaControl.FindUser(
sLogonName
)
Parameters
-
sLogonName
-
Type: String
A string value that contains the user's logon name.
Return value
Returns an object expression that evaluates to the user's DIDiskQuotaUser object.
Remarks
This method returns a DIDiskQuotaUser object even if there is no entry for the user in the quota file. The returned user object has warning threshold and hard quota limits set to the volume's default values.
The string returned from TranslateLogonNameToSID may be passed in place of the sLogonName parameter. When FindUser receives a SID string it uses the corresponding SID for direct lookup of the user's quota record on the volume. This bypasses the SID-name cache. In cases where FindUser fails due to a mismatch in format (for example, SAM-compatible and UPN) of the logon name provided and the logon name cached, the logon name can be translated to a SID string using TranslateLogonNameToSID then passed again to FindUser. The following VBScript code illustrates this technique.
Function Find(dqc, name)
On Error Resume Next
SET Find = dqc.FindUser(name)
If Err.Number <> 0 Then
Err.Clear
SET Find = dqc.FindUser(dqc.TranslateLogonNameToSID(name))
End If
End Function