CIM_NetworkPort class
NetworkPort is the logical representation of network communications hardware such as a physical connector and the setup or operation of the network chips, at the lowest layers of a network stack.
The following syntax is simplified from Managed Object Format (MOF) code and includes all of the inherited properties.
Syntax
[UMLPackagePath("CIM::Device::Ports"), Version("2.10.0"), AMENDMENT]
class CIM_NetworkPort : CIM_LogicalPort
{
string InstanceID;
string Caption;
string Description;
string ElementName;
datetime InstallDate;
string Name;
uint16 OperationalStatus[];
string StatusDescriptions[];
string Status;
uint16 HealthState;
uint16 CommunicationStatus;
uint16 DetailedStatus;
uint16 OperatingStatus;
uint16 PrimaryStatus;
uint16 EnabledState = 5;
string OtherEnabledState;
uint16 RequestedState = 12;
uint16 EnabledDefault = 2;
datetime TimeOfLastStateChange;
uint16 TransitioningToState = 12;
uint16 AvailableRequestedStates[];
string SystemCreationClassName;
string SystemName;
string CreationClassName;
string DeviceID;
boolean PowerManagementSupported;
uint16 PowerManagementCapabilities[];
uint16 Availability;
uint16 StatusInfo;
uint32 LastErrorCode;
string ErrorDescription;
boolean ErrorCleared;
string OtherIdentifyingInfo[];
uint64 PowerOnHours;
uint64 TotalPowerOnHours;
string IdentifyingDescriptions[];
uint16 AdditionalAvailability[];
uint64 MaxQuiesceTime;
uint64 MaxSpeed;
uint64 RequestedSpeed;
uint16 UsageRestriction;
uint16 PortType;
string OtherPortType;
uint64 Speed;
string OtherNetworkPortType;
uint16 PortNumber;
uint16 LinkTechnology;
string OtherLinkTechnology;
string PermanentAddress;
string NetworkAddresses[];
boolean FullDuplex;
boolean AutoSense;
uint64 SupportedMaximumTransmissionUnit;
uint64 ActiveMaximumTransmissionUnit;
};
Members
The CIM_NetworkPort class has these types of members:
Methods
The CIM_NetworkPort class has these methods.
Method | Description |
---|---|
EnableDevice | This method has been deprecated in lieu of the more general RequestStateChange method that directly overlaps with the functionality provided by this method. This method is inherited from CIM_LogicalDevice. |
OnlineDevice | This method has been deprecated in lieu of the more general RequestStateChange method that directly overlaps with the functionality provided by this method. This method is inherited from CIM_LogicalDevice. |
QuiesceDevice | This method has been deprecated in lieu of the more general RequestStateChange method that directly overlaps with the functionality provided by this method. This method is inherited from CIM_LogicalDevice. |
RequestStateChange | Requests that the state of the element be changed to the value specified in the RequestedState parameter. When the requested state change takes place, the enabled state and requested state of the element will be the same. Invoking the RequestChangeState method multiple times could result in earlier requests being overwritten or lost. If 0 is returned, then the task completed successfully and the use of CIM_ConcreteJob was not required. If 4096 (0x1000) is returned, then the task will take some time to complete, CIM_ConcreteJob will be created, and its reference returned in the output parameter Job. Any other return code indicates an error condition. This method is inherited from CIM_EnabledLogicalElement. |
Reset | Requests a reset of the logical device. This method is inherited from CIM_LogicalDevice. |
RestoreProperties | Requests that the Device re-establish its configuration, setup and/or state information from a backing store. This method is inherited from CIM_LogicalDevice. |
SaveProperties | Requests that the Device capture its current configuration, setup and/or state information in a backing store. This method is inherited from CIM_LogicalDevice. |
SetPowerState | Sets the power state of the Device. The use of this method has been deprecated. Instead, use the SetPowerState method in the associated PowerManagementService class. This method is inherited from CIM_LogicalDevice. |
Properties
The CIM_NetworkPort class has these properties.
-
ActiveMaximumTransmissionUnit
-
-
Data type: uint64
-
Access type: Read-only
-
Qualifiers: PUnit ("byte"), Units ("Bytes")
The active or negotiated maximum transmission unit (MTU) that can be supported.
-
-
AdditionalAvailability
-
-
Data type: uint16 array
-
Access type: Read-only
-
Qualifiers: ModelCorrespondence ("CIM_LogicalDevice.Availability")
Additional availability and status of the Device, beyond that specified in the Availability property. The Availability property denotes the primary status and availability of the Device. In some cases, this will not be sufficient to denote the complete status of the Device. In those cases, the AdditionalAvailability property can be used to provide further information. For example, a Device\'s primary Availability may be "Off line" (value=8), but it may also be in a low power state (AdditonalAvailability value=14), or the Device could be running Diagnostics (AdditionalAvailability value=5, "In Test").
This property is inherited from CIM_LogicalDevice.
-
Other (1)
-
Unknown (2)
-
Running/Full Power (3)
-
Warning (4)
-
In Test (5)
-
Not Applicable (6)
-
Power Off (7)
-
Off Line (8)
-
Off Duty (9)
-
Degraded (10)
-
Not Installed (11)
-
Install Error (12)
-
Power Save - Unknown (13)
-
Power Save - Low Power Mode (14)
-
Power Save - Standby (15)
-
Power Cycle (16)
-
Power Save - Warning (17)
-
Paused (18)
-
Not Ready (19)
-
Not Configured (20)
-
Quiesced (21)
-
-
AutoSense
-
-
Data type: boolean
-
Access type: Read-only
A Boolean that indicates whether the NetworkPort is capable of automatically determining the speed or other communications characteristics of the attached network media.
-
-
Availability
-
-
Data type: uint16
-
Access type: Read-only
-
Qualifiers: ModelCorrespondence ("CIM_LogicalDevice.AdditionalAvailability")
The primary availability and status of the Device. (Additional status information can be specified using the Additional Availability array property.)
This property is inherited from CIM_LogicalDevice.
Value Meaning - Other
- 1
- Unknown
- 2
- Running/Full Power
- 3
- Warning
- 4
- In Test
- 5
- Not Applicable
- 6
- Power Off
- 7
- Off Line
- 8
- Off Duty
- 9
- Degraded
- 10
- Not Installed
- 11
- Install Error
- 12
- Power Save - Unknown
- 13
The Device is known to be in a power save mode, but its exact status in this mode is unknown - Power Save - Low Power Mode
- 14
The Device is in a power save state but still functioning, and may exhibit degraded performance - Power Save - Standby
- 15
The Device is not functioning but could be brought to full power quickly. - Power Cycle
- 16
- Power Save - Warning
- 17
The Device is in a warning state, though also in a power save mode. - Paused
- 18
- Not Ready
- 19
- Not Configured
- 20
- Quiesced
- 21
-
-
AvailableRequestedStates
-
-
Data type: uint16 array
-
Access type: Read-only
-
Qualifiers: ModelCorrespondence ("CIM_EnabledLogicalElement.RequestStateChange", "CIM_EnabledLogicalElementCapabilities.RequestedStatesSupported")
AvailableRequestedStates indicates the possible values for the RequestedState parameter of the method RequestStateChange, used to initiate a state change. The values listed shall be a subset of the values contained in the RequestedStatesSupported property of the associated instance of CIM_EnabledLogicalElementCapabilities where the values selected are a function of the current state of the CIM_EnabledLogicalElement. This property may be non-null if an implementation is able to advertise the set of possible values as a function of the current state. This property shall be null if an implementation is unable to determine the set of possible values as a function of the current state.
This property is inherited from CIM_EnabledLogicalElement.
-
Enabled (2)
-
Disabled (3)
-
Shut Down (4)
-
Offline (6)
-
Test (7)
-
Defer (8)
-
Quiesce (9)
-
Reboot (10)
-
Reset (11)
-
DMTF Reserved (12 65535)
-
-
Caption
-
-
Data type: string
-
Access type: Read-only
-
Qualifiers: MaxLen (64)
Contains a short textual description of the object.
This property is inherited from CIM_ManagedElement.
-
-
CommunicationStatus
-
-
Data type: uint16
-
Access type: Read-only
Indicates the ability of the instrumentation to communicate with this element. A NULL value indicates that instrumentation does not support this property.
This property is inherited from CIM_ManagedSystemElement.
Values Meaning - Unknown
- 0
Indicates that the instrumentation cannot report on the CommunicationStatus property at this time. - Not Available
- 1
Indicates that the instrumentation is capable of reporting this property, but intentionally does not for this element. - Communication OK
- 2
Indicates only that communication is established with the element. - Lost Communication
- 3
Indicates that the element has been contacted in the past, but is currently unreachable. - No Contact
- 4
Indicates that the instrumentation has contact information for this element, but has never been able to communicate with it. - DMTF Reserved
- 5 32767
Reserved. - Vendor Reserved
- 32768 = value
Reserved. -
-
CreationClassName
-
Indicates the name of the class or the subclass used in the creation of an instance. When used with the other key properties of this class, this property allows all instances of this class and its subclasses to be uniquely identified.
This property is inherited from CIM_LogicalDevice.
-
Description
-
-
Data type: string
-
Access type: Read-only
Provides a textual description of the object.
This property is inherited from CIM_ManagedElement.
-
-
DetailedStatus
-
-
Data type: uint16
-
Access type: Read-only
-
Qualifiers: ModelCorrespondence ("CIM_EnabledLogicalElement.PrimaryStatus", "CIM_ManagedSystemElement.HealthState")
Indicates additional status details that complement the PrimaryStatus property. A NULL value indicates that the instrumentation does not support this property.
This property is inherited from CIM_ManagedSystemElement.
Values Meaning - Not Available
- 0
Indicates that the instrumentation is capable of reporting this property, but intentionally does not report it for this element. - No Additional Information
- 1
Indicates that no details have to be added to the PrimaryStatus property, for example when the PrimaryStatus is set to OK. - Stressed
- 2
Indicates that the element functions, but requires attention. Overload and overheated are examples of Stressed states. - Predictive Failure
- 3
Indicates that an element functions nominally, but predicts a failure in the near future. - Non-Recoverable Error
- 4
Indicates that this element is in an error condition that requires human intervention. - Supporting Entity in Error
- 5
Indicates that an element on which this element depends is in error. This element might be OK but cannot function because of the state of a dependent element. An example is a network service or endpoint that cannot function due to lower-layer networking problems. - DMTF Reserved
- 6 32767
Reserved. - Vendor Reserved
- 32768 = value
Reserved. -
-
DeviceID
-
An address or other identifying information to uniquely name the logical device
This property is inherited from CIM_LogicalDevice.
-
ElementName
-
-
Data type: string
-
Access type: Read-only
Contains a user-friendly name for the object. This property allows each instance to define a user-friendly name in addition to its key properties, identity data, and description information.
This property is inherited from CIM_ManagedElement.
-
-
EnabledDefault
-
-
Data type: uint16
-
Access type: Read/write
An enumerated value indicating an administrator's default or startup configuration for the Enabled State of an element. By default, the element is "Enabled" (value=2).
This property is inherited from CIM_EnabledLogicalElement.
-
Enabled (2)
-
Disabled (3)
-
Not Applicable (5)
-
Enabled but Offline (6)
-
No Default (7)
-
Quiesce (9)
-
DMTF Reserved (10 32767)
-
Vendor Reserved (32768 65535)
-
-
EnabledState
-
-
Data type: uint16
-
Access type: Read-only
-
Qualifiers: ModelCorrespondence ("CIM_EnabledLogicalElement.OtherEnabledState")
Indicates the enabled and disabled states of an element. It can also indicate the transitions between these requested states. For example, shutting down (value=4) and starting (value=10) are transient states between enabled and disabled.
This property is inherited from CIM_EnabledLogicalElement.
Value Meaning - Unknown
- 0
- Other
- 1
- Enabled
- 2
The element is or could be executing commands, will process any queued commands, and queues new requests. - Disabled
- 3
The element will not execute commands and will drop any new requests. - Shutting Down
- 4
The element is in the process of going to a Disabled state. - Not Applicable
- 5
The element does not support being enabled or disabled. - Enabled but Offline
- 6
The element might be completing commands, and will drop any new requests. - In Test
- 7
The element is in a test state. - Deferred
- 8
The element might be completing commands, but will queue any new requests. - Quiesce
- 9
The element is enabled but in a restricted mode. The behavior of the element is similar to the Enabled state (2), but it processes only a restricted set of commands. All other requests are queued. - Starting
- 10
The element is in the process of going to an Enabled state (2). New requests are queued. - DMTF Reserved
- 11 32767
Reserved. - Vendor Reserved
- 32768 65535
Reserved. -
-
ErrorCleared
-
-
Data type: boolean
-
Access type: Read-only
-
Qualifiers: Deprecated ("CIM_ManagedSystemElement.OperationalStatus")
A boolean property indicating that the error reported in LastErrorCode is now cleared.
This property is inherited from CIM_LogicalDevice.
-
-
ErrorDescription
-
-
Data type: string
-
Access type: Read-only
-
Qualifiers: Deprecated ("CIM_DeviceErrorData.ErrorDescription")
A free-form string supplying more information about the error recorded in LastErrorCode, and information on any corrective actions that may be taken.
This property is inherited from CIM_LogicalDevice.
-
-
FullDuplex
-
-
Data type: boolean
-
Access type: Read-only
Boolean that indicates that the port is operating in full duplex mode.
-
-
HealthState
-
-
Data type: uint16
-
Access type: Read-only
Indicates the current health of the element. This attribute expresses the health of this element but not necessarily that of its sub-components.
This property is inherited from CIM_ManagedSystemElement.
Values Meaning - Unknown
- 0
The implementation cannot report on HealthState at this time. - OK
- 5
The element is fully functional and is operating within normal operational parameters and without error. - Degraded/Warning
- 10
The element is in working order and all functionality is provided. However, the element is not working to the best of its abilities. For example, the element might not be operating at optimal performance or it might be reporting recoverable errors - Minor failure
- 15
All functionality is available but some might be degraded. - Major failure
- 20
The element is failing. It is possible that some or all of the functionality of this component is degraded or not working. - Critical failure
- 25
The element is non-functional and recovery might not be possible. - Non-recoverable error
- 30
The element has completely failed, and recovery is not possible. All functionality provided by this element has been lost. - DMTF Reserved
- 31 = value
DMTF has reserved the unused portion of the continuum for additional HealthStates values in the future. -
-
IdentifyingDescriptions
-
-
Data type: string array
-
Access type: Read-only
-
Qualifiers: ArrayType ("Indexed"), ModelCorrespondence ("CIM_LogicalDevice.OtherIdentifyingInfo")
An array of free-form strings providing explanations and details behind the entries in the OtherIdentifyingInfo array. Note, each entry of this array is related to the entry in OtherIdentifyingInfo that is located at the same index.
This property is inherited from CIM_LogicalDevice.
-
-
InstallDate
-
-
Data type: datetime
-
Access type: Read-only
Indicates when the object was installed. The lack of a value does not indicate that the object is not installed.
This property is inherited from CIM_ManagedSystemElement.
-
-
InstanceID
-
-
Data type: string
-
Access type: Read-only
Uniquely and opaquely identifies an instance of this class within the scope of the containing Namespace.
[!Important]In order to ensure uniqueness within the Namespace, the value of InstanceID should be constructed in the following pattern:
OrgID:LocalID
OrgID must include a copyrighted, trademarked or otherwise unique name that is owned by the business entity defining the InstanceID, or be a registered ID that is assigned by a recognized global authority. This is similar to the structure of Schema class names. In addition, to ensure uniqueness the first colon in InstanceID must be between the OrgID andLocalID. Therefor the OrgID must not contain a colon (':').
LocalID is chosen by the business entity and should not be re-used to identify different underlying real-world elements.
If the preceding pattern is not used, the defining entity must assure that the resultant InstanceID is not re-used across any InstanceIDs produced by this or other providers for this Namespace.
For Distributed Management Task Force (DMTF) defined instances, the pattern must be used with the OrgID set to CIM.
This property is inherited from CIM_ManagedElement.
-
-
LastErrorCode
-
-
Data type: uint32
-
Access type: Read-only
-
Qualifiers: Deprecated ("CIM_DeviceErrorData.LastErrorCode")
Captures the last error code reported by the logical device.
This property is inherited from CIM_LogicalDevice.
-
-
LinkTechnology
-
-
Data type: uint16
-
Access type: Read-only
-
Qualifiers: ModelCorrespondence ("CIM_NetworkPort.OtherLinkTechnology")
An enumeration of the types of links. When set to 1 ("Other"), the related property OtherLinkTechnology contains a string description of the type of link.
-
Unknown (0)
-
Other (1)
-
Ethernet (2)
-
IB (3)
-
FC (4)
-
FDDI (5)
-
ATM (6)
-
Token Ring (7)
-
Frame Relay (8)
-
Infrared (9)
-
BlueTooth (10)
-
Wireless LAN (11)
-
-
MaxQuiesceTime
-
-
Data type: uint64
-
Access type: Read-only
-
Qualifiers: Deprecated ("No value"), Units ("MilliSeconds")
This property has been deprecated. When evaluating the use of Quiesce, it was determined that this single property is not adequate for describing when a device will automatically exit a quiescent state. In fact, the most likely scenario for a device to exit a quiescent state was determined to be based on the number of outstanding requests queued rather than on a maximum time. This will be re-evaluated and repositioned later.
Maximum time in milliseconds, that a Device can run in a "Quiesced" state. A Device's state is defined in its Availability and AdditionalAvailability properties, where "Quiesced" is conveyed by the value 21. What occurs at the end of the time limit is device-specific. The Device may unquiesce, may offline or take other action. A value of 0 indicates that a Device can remain quiesced indefinitely.
This property is inherited from CIM_LogicalDevice.
-
-
MaxSpeed
-
-
Data type: uint64
-
Access type: Read-only
-
Qualifiers: PUnit ("bit / second"), Units ("Bits per Second")
The maximum bandwidth of the Port in Bits per Second.
This property is inherited from CIM_LogicalPort.
-
-
Name
-
-
Data type: string
-
Access type: Read-only
-
Qualifiers: MaxLen (1024)
Indicates the user-friendly name for this instance of a job. In addition, the user-friendly name can be used as a property for a search or query.
[!Tip]
Name does not have to be unique within a namespace.This property is inherited from CIM_ManagedSystemElement.
-
-
NetworkAddresses
-
-
Data type: string array
-
Access type: Read-only
-
Qualifiers: MaxLen (64)
An array of strings that indicates the network addresses for the port.
-
-
OperatingStatus
-
-
Data type: uint16
-
Access type: Read-only
-
Qualifiers: ModelCorrespondence ("CIM_EnabledLogicalElement.EnabledState")
Indicates the current operational condition of the element. This property can be used to provide more detail about the current state of the element. It can also indicate transitional states. A NULL value indicates that the instrumentation does not support this property.
This property is inherited from CIM_ManagedSystemElement.
Value Meaning - Unknown
- 0
Indicates that the instrumentation cannot report on the OperatingStatus property at this time. - Not Available
- 1
Indicates that the instrumentation is capable of reporting this property, but intentionally does not report it for this element. - Servicing
- 2
Indicates that the element is in process to be configured, maintained, cleaned, or otherwise administered. - Starting
- 3
Indicates that the element is being initialized. - Stopping
- 4
Indicates that the element is being brought to an orderly stop. - Stopped
- 5
Indicates that the element is intentionally stopped. - Aborted
- 6
Indicates that the element stopped in an unexpected way. - Dormant
- 7
Indicates that the element is inactive or quiesced. - Completed
- 8
Indicates that the element completed its operation. We recommend using a PrimaryStatus property value of OK, Error, or Degraded to indicate success or failure of the operation. - Migrating
- 9
Indicates that the element is being moved between host elements. - Emigrating
- 10
Indicates that the element is being moved away from the host element. - Immigrating
- 11
Indicates that the element is being moved to a new host element. - Snapshotting
- 12
Indicates that a snapshot copy of the element is being created. - Shutting Down
- 13
Indicates that the element is being brought to an abrupt stop. - In Test
- 14
Indicates that the element is performing test functions. - Transitioning
- 15
Indicates that the element is between states and is not fully available in either state. Use another value that indicates a more specific transition if one is available. - In Service
- 16
Indicates that the element is in service and operational. - DMTF Reserved
- 17 32767
Reserved. - Vendor Reserved
- 32768 = value
Reserved. -
-
OperationalStatus
-
-
Data type: uint16 array
-
Access type: Read-only
-
Qualifiers: ArrayType ("Indexed"), ModelCorrespondence ("CIM_ManagedSystemElement.StatusDescriptions")
Contains indicators of the current status of the element. The first value of OperationalStatus should contain the primary status for the element.
Note
OperationalStatus replaces the deprecated Status property. Due to the widespread use of the existing Status property in management applications, Microsoft strongly recommends that providers or instrumentation provide both the Status and OperationalStatus properties. When instrumented, Status (because it is single-valued) should also provide the primary status of the element.
This property is inherited from CIM_ManagedSystemElement.
Values Meaning - Unknown
- 0
Indicates the implementation cannot report on OperationalStatus at this time. - Other
- 1
Indicates an undefined state. - OK
- 2
Indicates full functionality without errors. - Degraded
- 3
Indicates the element is working and all functionality is provided. However, the element is not working to the best of its abilities. For example, the element might not be operating at optimal performance or it might be reporting recoverable errors - Stressed
- 4
Indicates that the element is functioning, but needs attention. Overload and overheated are examples of Stressed states. - Predictive Failure
- 5
Indicates that an element is functioning nominally but predicting a failure in the near future. - Error
- 6
Indicates that an error has occurred. - Non-Recoverable Error
- 7
A nonrecoverable error has occurred. - Starting
- 8
The job is starting. - Stopping
- 9
The job is stopping. - Stopped
- 10
The element has been intentionally stopped. - In Service
- 11
Indicates the element is being configured, maintained, cleaned, or otherwise administered. - No Contact
- 12
Indicates that the monitoring system has knowledge of this element, but has never been able to establish communications with it. - Lost Communication
- 13
Indicates that the job is known to exist and has been contacted successfully in the past, but is currently unreachable. - Aborted
- 14
Indicates the job stopped in an unexpected way. The state and configuration of the job might need to be updated. - Dormant
- 15
Indicates that the job is inactive. - Supporting Entity in Error
- 16
Indicates that an element on which this job depends is in error. This element may be OK but is unable to function because of the state of a dependent element. An example is a network service or endpoint that cannot function due to lower-layer networking problems. - Completed
- 17
Indicates that the job has completed its operation. This value should be combined with either OK, ErrorError, or Degraded so that a client can tell if the complete operation Completed with OK (passed), Completed with Error (failed), or Completed with Degraded (the operation finished, but it did not complete OK or did not report an error). - Power Mode
- 18
"Power Mode" indicates that the element has additional power model information contained in the associated PowerManagementService association. - DMTF Reserved
- 19 32767
DMTF has reserved this portion of the range for additional OperationalStatus values in the future. - Vendor Reserved
- 32768 65535
Microsoft has reserved the unused portion of the range for additional OperationalStatus values in the future. -
-
OtherEnabledState
-
-
Data type: string
-
Access type: Read-only
-
Qualifiers: ModelCorrespondence ("CIM_EnabledLogicalElement.EnabledState")
A string that describes the enabled or disabled state of the element when the EnabledState property is set to 1 ("Other"). This property must be set to null when EnabledState is any value other than 1.
This property is inherited from CIM_EnabledLogicalElement.
-
-
OtherIdentifyingInfo
-
-
Data type: string array
-
Access type: Read-only
-
Qualifiers: ArrayType ("Indexed"), MaxLen (256), ModelCorrespondence ("CIM_LogicalDevice.IdentifyingDescriptions")
Captures additional data, beyond DeviceID information, that could be used to identify a logical device. One example would be to hold the Operating System\'s user friendly name for the Device in this property.
This property is inherited from CIM_LogicalDevice.
-
-
OtherLinkTechnology
-
-
Data type: string
-
Access type: Read-only
-
Qualifiers: ModelCorrespondence ("CIM_NetworkPort.LinkTechnology")
Describes LinkTechnology when it is set to 1, "Other".
-
-
OtherNetworkPortType
-
-
Data type: string
-
Access type: Read-only
-
Qualifiers: Deprecated ("CIM_NetworkPort.OtherPortType"), ModelCorrespondence ("CIM_LogicalPort.PortType")
Note: The use of this property is deprecated in lieu of CIM_LogicalPort.PortType.
Deprecated description: The type of module, when PortType is set to 1 ("Other".)
-
-
OtherPortType
-
-
Data type: string
-
Access type: Read-only
-
Qualifiers: ModelCorrespondence ("CIM_LogicalPort.PortType")
Describes the type of module, when PortType is set to 1 ("Other").
This property is inherited from CIM_LogicalPort.
-
-
PermanentAddress
-
-
Data type: string
-
Access type: Read-only
-
Qualifiers: MaxLen (64)
Defines the network address that is hardcoded into a port. This \'hardcoded\' address can be changed using a firmware upgrade or a software configuration. When this change is made, the field should be updated at the same time. PermanentAddress should be left blank if no \'hardcoded\' address exists for the NetworkAdapter.
-
-
PortNumber
-
-
Data type: uint16
-
Access type: Read-only
NetworkPorts are often numbered relative to either a logical module or a network element.
-
-
PortType
-
-
Data type: uint16
-
Access type: Read-only
-
Qualifiers: ModelCorrespondence ("CIM_NetworkPort.OtherNetworkPortType")
Defined to force consistent naming of the Type property in subclasses and to guarantee unique enum values for all instances of NetworkPort. When set to 1 ("Other"), related property OtherPortType contains a string description of the type of port. A range of values, DMTF_Reserved, has been defined that allows subclasses to override and define their specific types of ports.
This property is inherited from CIM_LogicalPort.
-
Unknown (0)
-
Other (1)
-
Not Applicable (2)
-
DMTF Reserved (3 15999)
-
Vendor Reserved (16000 65535)
-
-
PowerManagementCapabilities
-
-
Data type: uint16 array
-
Access type: Read-only
-
Qualifiers: Deprecated ("CIM_PowerManagementCapabilities.PowerCapabilities")
An enumerated array describing the power management capabilities of the Device. The use of this property has been deprecated. Instead, the PowerCapabilites property in an associated PowerManagementCapabilities class should be used.
This property is inherited from CIM_LogicalDevice.
-
Unknown (0)
-
Not Supported (1)
-
Disabled (2)
-
Enabled (3)
-
Power Saving Modes Entered Automatically (4)
-
Power State Settable (5)
-
Power Cycling Supported (6)
-
Timed Power On Supported (7)
-
-
PowerManagementSupported
-
-
Data type: boolean
-
Access type: Read-only
-
Qualifiers: Deprecated ("CIM_PowerManagementCapabilities")
Boolean indicating that the Device can be power managed. The use of this property has been deprecated. Instead, the existence of an associated PowerManagementCapabilities class (associated using the ElementCapabilities relationship) indicates that power management is supported.
This property is inherited from CIM_LogicalDevice.
-
-
PowerOnHours
-
-
Data type: uint64
-
Access type: Read-only
-
Qualifiers: Counter, Units ("Hours")
The number of consecutive hours that this Device has been powered, since its last power cycle.
This property is inherited from CIM_LogicalDevice.
-
-
PrimaryStatus
-
-
Data type: uint16
-
Access type: Read-only
-
Qualifiers: ModelCorrespondence ("CIM_ManagedSystemElement.DetailedStatus", "CIM_ManagedSystemElement.HealthState")
Indicates a high-level status value.
This property is inherited from CIM_ManagedSystemElement.
The possible values are.
-
Unknown (0)
-
OK (1)
-
Degraded (2)
-
Error (3)
-
DMTF Reserved (4 32767)
-
Vendor Reserved (32768 = value )
-
-
RequestedSpeed
-
-
Data type: uint64
-
Access type: Read/write
-
Qualifiers: ModelCorrespondence ("CIM_LogicalPort.Speed"), PUnit ("bit / second"), Units ("Bits per Second")
The requested bandwidth of the Port in Bits per Second. The actual bandwidth is reported in LogicalPort.Speed.
This property is inherited from CIM_LogicalPort.
-
-
RequestedState
-
-
Data type: uint16
-
Access type: Read-only
-
Qualifiers: ModelCorrespondence ("CIM_EnabledLogicalElement.EnabledState")
RequestedState is an integer enumeration that indicates the last requested or desired state for the element. The actual state of the element is represented by EnabledState. This property is provided to compare the last requested and current enabled or disabled states. Note that when EnabledState is set to 5 ("Not Applicable"), then this property has no meaning. By default, the RequestedState of the element is 5 ("No Change"). Refer to the EnabledState property description for explanations of the values in the RequestedState enumeration. It should be noted that there are two new values in RequestedState that build on the statuses of EnabledState. These are "Reboot" (10) and "Reset" (11). Reboot refers to doing a "Shut Down" and then moving to an "Enabled" state. Reset indicates that the element is first "Disabled" and then "Enabled". The distinction between requesting "Shut Down" and "Disabled" should also be noted. Shut Down requests an orderly transition to the Disabled state, and might involve removing power, to completely erase any existing state. The Disabled state requests an immediate disabling of the element, such that it will not execute or accept any commands or processing requests. This property is set as the result of a method invocation (such as StartService or StopService on CIM_Service), or can be overridden and defined as WRITEable in a subclass. The method approach is considered superior to a WRITEable property, because it allows an explicit invocation of the operation and the return of a result code. A particular instance of CIM_EnabledLogicalElement might not support RequestStateChange. If this occurs, the value 12 ("Not Applicable") is used.
This property is inherited from CIM_EnabledLogicalElement.
-
Unknown (0)
-
Enabled (2)
-
Disabled (3)
-
Shut Down (4)
-
No Change (5)
-
Offline (6)
-
Test (7)
-
Deferred (8)
-
Quiesce (9)
-
Reboot (10)
-
Reset (11)
-
Not Applicable (12)
-
DMTF Reserved (13 32767)
-
Vendor Reserved (32768 65535)
-
-
Speed
-
-
Data type: uint64
-
Access type: Read-only
-
Qualifiers: PUnit ("bit / second"), Override ("Speed"), Units ("Bits per Second")
The current bandwidth of the Port in Bits per Second. For ports that vary in bandwidth or for those where no accurate estimation can be made, this property should contain the nominal bandwidth.
-
-
Status
-
-
Data type: string
-
Access type: Read-only
-
Qualifiers: Deprecated ("CIM_ManagedSystemElement.OperationalStatus"), MaxLen (10)
Contains a string indicating the primary status of the object.
Note
This property is deprecated and replaced by the OperationalStatus property. If you choose to use the Status property for backward compatibility it should be secondary to the OperationalStatus property.
This property is inherited from CIM_ManagedSystemElement.
The possible values are.
-
("OK")
-
("Error")
-
("Degraded")
-
("Unknown")
-
("Pred Fail")
-
("Starting")
-
("Stopping")
-
("Service")
-
("Stressed")
-
("NonRecover")
-
("No Contact")
-
("Lost Comm")
-
("Stopped")
-
-
StatusDescriptions
-
-
Data type: string array
-
Access type: Read-only
-
Qualifiers: ArrayType ("Indexed"), ModelCorrespondence ("CIM_ManagedSystemElement.OperationalStatus")
Indicates descriptions of the corresponding values in the OperationalStatus array. For example, if an element in the OperationalStatus property contains the value Stopping, then the element at the same array index in this property might contain an explanation as to why an object is being stopped.
This property is inherited from CIM_ManagedSystemElement.
-
-
StatusInfo
-
-
Data type: uint16
-
Access type: Read-only
-
Qualifiers: Deprecated ("CIM_EnabledLogicalElement.EnabledState")
Indicates whether the Logical Device is in an enabled (value = 3), disabled (value = 4) or some other (1) or unknown (2) state. If this property does not apply to the LogicalDevice, the value, 5 ("Not Applicable"), should be used. StatusInfo has been deprecated in lieu of a more clearly named property with additional enumerated values (EnabledState), that is inherited from CIM_ManagedSystemElement.
This property is inherited from CIM_LogicalDevice.
-
Other (1)
-
Unknown (2)
-
Enabled (3)
-
Disabled (4)
-
Not Applicable (5)
-
-
SupportedMaximumTransmissionUnit
-
-
Data type: uint64
-
Access type: Read-only
-
Qualifiers: PUnit ("byte"), Units ("Bytes")
The maximum transmission unit (MTU) that can be supported.
-
-
SystemCreationClassName
-
-
Data type: string
-
Access type: Read-only
-
Qualifiers: key, MaxLen (256), Propagated ("CIM_System.CreationClassName")
The scoping System's CreationClassName.
This property is inherited from CIM_LogicalDevice.
-
-
SystemName
-
-
Data type: string
-
Access type: Read-only
-
Qualifiers: key, MaxLen (256), Propagated ("CIM_System.Name")
The scoping System's Name.
This property is inherited from CIM_LogicalDevice.
-
-
TimeOfLastStateChange
-
-
Data type: datetime
-
Access type: Read-only
The date or time when the enabled state of the element last changed. If the state of the element has not changed and this property is populated, then it must be set to a 0 interval value. If a state change was requested, but rejected or not yet processed, the property must not be updated.
This property is inherited from CIM_EnabledLogicalElement.
-
-
TotalPowerOnHours
-
-
Data type: uint64
-
Access type: Read-only
-
Qualifiers: Counter, Units ("Hours")
The total number of hours that this Device has been powered.
This property is inherited from CIM_LogicalDevice.
-
-
TransitioningToState
-
-
Data type: uint16
-
Access type: Read-only
-
Qualifiers: ModelCorrespondence ("CIM_EnabledLogicalElement.RequestStateChange", "CIM_EnabledLogicalElement.RequestedState", "CIM_EnabledLogicalElement.EnabledState")
TransitioningToState indicates the target state to which the instance is transitioning.
A value of 5 "No Change" shall indicate that no transition is in progress.A value of 12 "Not Applicable" shall indicate the implementation does not support representing ongoing transitions.
A value other than 5 or 12 shall identify the state to which the element is in the process of transitioning.
This property is inherited from CIM_EnabledLogicalElement.
-
Unknown (0)
-
Enabled (2)
-
Disabled (3)
-
Shut Down (4)
-
No Change (5)
-
Offline (6)
-
Test (7)
-
Defer (8)
-
Quiesce (9)
-
Reboot (10)
-
Reset (11)
-
Not Applicable (12)
-
DMTF Reserved (13 65535)
-
-
UsageRestriction
-
-
Data type: uint16
-
Access type: Read-only
In some circumstances, a LogicalPort might be identifiable as a front end or back end port. An example of this situation would be a storage array that might have back end ports to communicate with disk drives and front end ports to communicate with hosts. If there is no restriction on the use of the port, then the value should be set to 'not restricted'.
This property is inherited from CIM_LogicalPort.
-
Unknown (0)
-
Front-end only (2)
-
Back-end only (3)
-
Not restricted (4)
-
Requirements
Minimum supported client |
Windows 8 |
Minimum supported server |
Windows Server 2012 |
Namespace |
Root\standardcimv2 |
MOF |
|
DLL |
|