S2D - Basic Verification Tests
Requirements: First run job "S2D - Prepare Machines for Tests", then "S2D - Setup Storage Cluster" (if S2D not already configured) on the cluster nodes and test controller. The BVT performs two types of tests: - Moving the CSV on top of Storage Spaces Direct between nodes while performing random write IO, and verifying that IO is uninterrupted and CSV does not fail. - Bringing down a node by stopping cluster service, killing cluster service, evict node, graceful machine restart, and non-graceful machine restart (with each action targeting a random node). Test also performs random write IO targeting the appropriate CSV during node failures and verifies that IO does not fail.
Test details
Specifications |
|
Platforms |
|
Supported Releases |
|
Expected run time (in minutes) | 120 |
Category | Scenario |
Timeout (in minutes) | 7200 |
Requires reboot | false |
Requires special configuration | true |
Type | automatic |
Additional documentation
Tests in this feature area might have additional documentation, including prerequisites, setup, and troubleshooting information, that can be found in the following topic(s):
More information
Parameters
Parameter name | Parameter description |
---|---|
ClusterName | name of storage cluster to target tests |
LogFileSSUFailure | File name for test log of SSU failure tests |
LogFileCSVMove | File name for test log of CSV move tests |
Troubleshooting
For generic troubleshooting of HLK test failures, see Troubleshooting Windows HLK Test Failures.