KSEVENT_TUNER_INITIATE_SCAN

The KSEVENT_TUNER_INITIATE_SCAN event requests that the driver initiate a scan operation and notify a user-mode client when the driver's associated tuning device completes the scan operation.

Usage Summary Table

Get Set Target Event descriptor type Event value type
No Yes Pin KSEVENT_TUNER_INITIATE_SCAN_S KSEVENTDATA

Remarks

Every scan request should be non-blocking. That is, the driver should not wait for the scan operation to complete before it returns control. In fact, the driver should use a separate thread to perform the scan operation.

While the KSEVENT_TUNER_INITIATE_SCAN event is independent of KSPROPERTY_TUNER_FREQUENCY, KSEVENT_TUNER_INITIATE_SCAN corresponds to the KS_TUNER_TUNING_EXACT tuning flag in the TuningFlags member of the KSPROPERTY_TUNER_FREQUENCY_S structure. This means that the scan always attempts to determine the exact frequency of the next channel. Also, the tuning strategy that the tuning device follows is controlled by the driver (KS_TUNER_STRATEGY_DRIVER_TUNES from the Strategy member of the KSPROPERTY_TUNER_MODE_CAPS_S structure). These fixed flags and strategy are always followed even if a different flag and strategy are used to control KSPROPERTY_TUNER_FREQUENCY.

In other words, KSTUNER_TUNING_FLAGS and KSTUNER_STRATEGY values do not affect the behavior of KSEVENT_TUNER_INITIATE_SCAN.

Completion and Status

The scan status property KSPROPERTY_TUNER_SCAN_STATUS provides information about the current frequency and the status of the signal lock. The application queries the lock status from the KSPROPERTY_TUNER_SCAN_STATUS property. The application also queries KSPROPERTY_TUNER_STANDARD_MODE property for information about automatic-signal-standard detection. If no signal was found in the requested range, the KSPROPERTY_TUNER_SCAN_STATUS property returns the Tuner_LockType_None value in the LockStatus member of the KSPROPERTY_TUNER_SCAN_STATUS_S structure. If the tuning device can automatically detect the tuner standard from the signal and a signal in an alternate standard was found, the tuning device itself can process any requests to the KSPROPERTY_TUNER_STANDARD property. The tuning device is possibly unable to proceed beyond a phased-lock-loop (PLL) lock, and it might specify that the standard is not known. Or, the tuning device might automatically adjust to a different signal standard. Also, the tuning device might even obtain a full lock on that signal standard and determine the alternate standard. Such situations might arise when there are multiple signal standards in the frequency spectrum.

Boundary Conditions

If the driver finds that the center frequency of a channel is outside the range that an application provides, the driver must ignore that signal and move to the next signal; the driver must not return the best possible approximation within the range provided. The driver must move to the next signal to avoid duplicate counting of channels when an application attempts to compile a channel list.

For the same reason, the application must shift the range of query by half the expected channel bandwidth (about 6/2 = 3MHz for analog and digital TV) to ensure that channels are not double counted particularly when the hardware encounters a signal that the hardware cannot decode. In this situation, the driver has difficulty avoiding double counting certain channels.

Multi-Standard Spectra

The scan operation must complete whenever a new channel or signal is found. The driver then returns scan status through the KSPROPERTY_TUNER_SCAN_STATUS property. The scan must complete whenever a new channel is found even if the driver determines that the newly found channel does not match the previously applied standard. The application must process the new channel information and must resubmit a scan request to find another channel with the same signal standard.

See also

KSEVENT_TUNER_INITIATE_SCAN_S

KSEVENTDATA

KSPROPERTY_TUNER_SCAN_STATUS

KSPROPERTY_TUNER_SCAN_CAPS

KSPROPERTY_TUNER_STANDARD

KSPROPERTY_TUNER_STANDARD_MODE