MB modem reset operations

This section defines MBIM CID commands and data structures, as well as NDIS OID commands and data structures, for resetting the modem in a mobile broadband (MB) device. These commands and data structures are available in Windows 10, version 1709 and later.

MBIM_CID_MS_DEVICE_RESET

The host sends MBIM_CID_MS_DEVICE_RESET to the MBIM function to reset the modem device.

Service name UUID UUID value
Microsoft Basic IP Connectivity Extensions UUID_BASIC_CONNECT_EXTENSIONS 3d01dcc5-fef5-4d05-0d3a-bef7058e9aaf
CID Command code Set Query Notify
MBIM_CID_MS_DEVICE_RESET 10 Y N N

Parameters

Type Set Query Notification
Command Empty Not applicable Not applicable
Response Empty Not applicable Not applicable

Query

Not applicable.

Set

The InformationBuffer shall be NULL and InformationBufferLength shall be zero.

Response

The InformationBuffer shall be NULL and InformationBufferLength shall be zero.

Notification

Not applicable.

Status codes

The following status codes are applicable. Status is returned as an asynchronous response to a set operation after reset is complete.

Status code Description
MBIM_STATUS_SUCCESS The operation succeeded.
MBIM_STATUS_BUSY The device is busy.
MBIM_STATUS_FAILURE The operation failed.
MBIM_STATUS_NO_DEVICE_SUPPORT The device does not support this operation.

OID_WWAN_DEVICE_RESET

The NDIS equivalent for MBIM_CID_MS_DEVICE_RESET is OID_WWAN_DEVICE_RESET.