Enable support for Clustered Windows Servers that use clustered RAID controllers
This article provides a solution to an issue where the validation may fail when you run a cluster validation wizard for Windows Server-based Failover Cluster.
Applies to: Windows Server 2008 R2 Service Pack 1
Original KB number: 2839292
Symptoms
When you run a cluster validation wizard for Windows Server 2008 R2-based or Windows Server 2012-based Failover Cluster, the validation may fail. Additionally, you may receive an error message that resembles the following:
Disk bus type does not support clustering
Cause
This problem occurs if the shared storage type used by the system is Direct Attached clustered RAID controllers.
Resolution
To resolve this problem, add a registry key that enables support for shared storage using Direct Attached clustered RAID controllers.
Important
This section, method, or task contains steps that tell you how to modify the registry. However, serious problems might occur if you modify the registry incorrectly. Therefore, make sure that you follow these steps carefully. For added protection, back up the registry before you modify it. Then, you can restore the registry if a problem occurs. For more information about how to back up and restore the registry, see How to back up and restore the registry in Windows.
To add the key to the registry, follow these steps:
Open Registry editor (regedit.exe).
Locate and then select the following registry subkey:
HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\ClusDisk\Parameters
Right-click Parameters and then select New.
Select DWORD and give it a name of AllowBusTypeRAID.
Once the key is created, give it a value of 0x01.
Click OK.
Exit the Registry editor.
Restart the computer.
More information
For more information on validated solutions for Cluster in a Box Validation Kit, visit the following article: