Share via


MSFT_WmiProvider_PutClassAsyncEvent_Post class

The MSFT_WmiProvider_PutClassAsyncEvent_Post event class represents an event generated immediately following completion of the provider's implementation of IWbemServices::PutClassAsync.

The following syntax is simplified from Managed Object Format (MOF) code and includes all inherited properties. Properties are listed in alphabetic order, not MOF order.

Syntax

[AMENDMENT]
class MSFT_WmiProvider_PutClassAsyncEvent_Post : Msft_WmiProvider_OperationEvent_Post
{
  uint8  SECURITY_DESCRIPTOR[];
  uint64 TIME_CREATED;
  String TransactionIdentifer;
  object ClassObject;
  uint32 Flags;
  string HostingGroup;
  uint32 HostingSpecification;
  string Locale;
  string Namespace;
  object ObjectParameter;
  string Provider;
  uint32 ResultCode;
  string StringParameter;
  string TransactionIdentifier;
  string User;
};

Members

The MSFT_WmiProvider_PutClassAsyncEvent_Post class has these types of members:

Properties

The MSFT_WmiProvider_PutClassAsyncEvent_Post class has these properties.

ClassObject

Data type: object

Access type: Read-only

Class definition.

Flags

Data type: uint32

Access type: Read-only

One or more of the following values are valid.

WBEM_FLAG_USE_AMENDED_QUALIFIERS

If this flag is set, WMI does not store any qualifiers with the amended flavor. If this flag is not set, it is assumed that this object is not localized, and all qualifiers are stored with this instance.

WBEM_FLAG_CREATE_OR_UPDATE

This flag causes this class to be created if it does not exist or be overwritten if it exists already.

WBEM_FLAG_UPDATE_ONLY

Updates an existing class.

WBEM_FLAG_CREATE_ONLY

This flag is for class creation only. The call fails if the class already exists.

WBEM_FLAG_SEND_STATUS

This flag registers with WMI a request to receive intermediate status reports through the client's implementation of IWbemObjectSink::SetStatus.

WBEM_FLAG_OWNER_UPDATE

Push providers must specify this flag when calling PutClassAsync to indicate that this class has changed.

WBEM_FLAG_UPDATE_COMPATIBLE

This flag allows a class to be updated if there are no derived classes and there are no instances for that class. It also allows updates in all cases if the change is just to non-important qualifiers (for example, the Description qualifier). This is the default behavior for this call and is used for compatibility with previous versions of WMI. If the class has instances or changes are to important qualifiers, the update fails.

WBEM_FLAG_UPDATE_SAFE_MODE

This flag allows updates of classes even if there are child classes, as long as the change does not cause any conflicts with child classes. An example of an update this flag would allow would be to add a new property to the base class that was not previously mentioned in any of the child classes. If the class has instances, the update fails.

WBEM_FLAG_UPDATE_FORCE_MODE

This flag forces updates of classes when conflicting child classes exist. An example of an update this flag would force would be if a class qualifier were defined in a child class, and the base class tried to add the same qualifier which conflicted with the existing one. In force mode, this conflict would be resolved by deleting the conflicting qualifier in the child class.

HostingGroup

Data type: string

Access type: Read-only

Second component of the __Win32Provider HostingModel property when the hosting model is one of "LocalSystemHost", "LocalSystemHostOrSelfHost", "NetworkServiceHost", or "LocalServiceHost". The hosting group defines a particular instantiation of a WMI provider host. Providers that share the same hosting model and hosting group share the same surrogate process.

This property is inherited from Msft_WmiProvider_OperationEvent

HostingSpecification

Data type: uint32

Access type: Read-only

The first component of the __Win32Provider HostingModel property. For the possible values of this property, see the HostingSpecification property in the MSFT_Providers class.

This property is inherited from Msft_WmiProvider_OperationEvent

Locale

Data type: string

Access type: Read-only

Particular instantiation of a provider instance when the provider is configured for per local initialization.

This property is inherited from Msft_WmiProvider_OperationEvent

Namespace

Data type: string

Access type: Read-only

Namespace associated with a particular provider instance.

This property is inherited from Msft_WmiProvider_OperationEvent

ObjectParameter

Data type: object

Access type: Read-only

Extended status passed through provider's IWbemObjectSink::SetStatus call, possible NULL.

Provider

Data type: string

Access type: Read-only

Name associated with a particular provider instance. The name is identical to the __Win32Provider property.

This property is inherited from Msft_WmiProvider_OperationEvent

ResultCode

Data type: uint32

Access type: Read-only

HRESULT status code of the operation.

SECURITY_DESCRIPTOR

Data type: uint8 array

Access type: Read-only

Descriptor that the event provider uses to determine which users can receive the event. For more information, see WMI Security Constants.

This property is inherited from __Event.

StringParameter

Data type: string

Access type: Read-only

This property is currently always NULL.

TIME_CREATED

Data type: uint64

Access type: Read-only

Unique value that indicates the time the event is generated. This is a 64-bit value that represents the number of 100-nanosecond intervals after January 1, 1601. The information is in the Coordinated Universal Time (UTC) format.

For more information about using uint64 values in scripts, see Scripting in WMI.

This property is inherited from __Event.

TransactionIdentifer

Data type: String

Access type: Read-only

The TransactionIdentifer property is for internal use, currently always empty.

This property is inherited from Msft_WmiProvider_OperationEvent.

TransactionIdentifier

Data type: string

Access type: Read-only

Internal use only. The current value is "{00000000-0000-0000-0000-000000000000}".

This property is inherited from Msft_WmiProvider_OperationEvent

User

Data type: string

Access type: Read-only

Particular provider instance, configured for per user initialization.

This property is inherited from Msft_WmiProvider_OperationEvent

Requirements

Minimum supported client
Windows Vista
Minimum supported server
Windows Server 2008
Namespace
Root\CIMV2
MOF
System.mof
DLL
WmiPrvSD.dll

See also

Msft_WmiProvider_OperationEvent_Post

Provider Event Troubleshooting Classes

MSFT_Providers

WMI Troubleshooting

WMI Troubleshooting

Receiving a WMI Event