Share via


MSFT_WmiProvider_CreateClassEnumAsyncEvent_Pre class

The MSFT_WmiProvider_CreateClassEnumAsyncEvent_Pre event class represents an event generated immediately prior to calling the provider's implementation of IWbemServices::CreateClassEnumAsync.

The following syntax is simplified from Managed Object Format (MOF) code and includes all inherited properties. Properties are listed in alphabetic order, not MOF order.

Syntax

[AMENDMENT]
class MSFT_WmiProvider_CreateClassEnumAsyncEvent_Pre : Msft_WmiProvider_OperationEvent_Pre
{
  uint8  SECURITY_DESCRIPTOR[];
  uint64 TIME_CREATED;
  String TransactionIdentifer;
  uint32 Flags;
  string HostingGroup;
  uint32 HostingSpecification;
  string Locale;
  string Namespace;
  string Provider;
  string SuperclassName;
  string TransactionIdentifier;
  string User;
};

Members

The MSFT_WmiProvider_CreateClassEnumAsyncEvent_Pre class has these types of members:

Properties

The MSFT_WmiProvider_CreateClassEnumAsyncEvent_Pre class has these properties.

Flags

Data type: uint32

Access type: Read-only

One or more of the following values are valid.

WBEM_FLAG_USE_AMENDED_QUALIFIERS

If this flag is set, WMI retrieves the amended qualifiers stored in the localized namespace of the current connection's locale. If not set, only the qualifiers stored in the immediate namespace are retrieved.

WBEM_FLAG_BIDIRECTIONAL

This flag causes WMI to retain pointers to objects of the enumeration until the client releases the enumerator.

WBEM_FLAG_DEEP

This flag forces the enumeration to include this and all subclasses in the hierarchy.

WBEM_FLAG_SHALLOW

This flag forces the enumeration to include only instances of this class, excluding all subclasses in the hierarchy.

WBEM_FLAG_SEND_STATUS

This flag registers with WMI a request to receive intermediate status reports through the client's implementation of IWbemObjectSink::SetStatus.

HostingGroup

Data type: string

Access type: Read-only

Second component of the __Win32Provider HostingModel property when the hosting model is one of "LocalSystemHost", "LocalSystemHostOrSelfHost", "NetworkServiceHost", or "LocalServiceHost". The hosting group defines a particular instantiation of a WMI provider host. Providers that share the same hosting model and hosting group share the same surrogate process.

This property is inherited from Msft_WmiProvider_OperationEvent

HostingSpecification

Data type: uint32

Access type: Read-only

The first component of the __Win32Provider HostingModel property. For the possible values of this property, see the HostingSpecification property in the MSFT_Providers class.

This property is inherited from Msft_WmiProvider_OperationEvent

Locale

Data type: string

Access type: Read-only

Particular instantiation of a provider instance when the provider is configured for per local initialization.

This property is inherited from Msft_WmiProvider_OperationEvent

Namespace

Data type: string

Access type: Read-only

Namespace associated with a particular provider instance.

This property is inherited from Msft_WmiProvider_OperationEvent

Provider

Data type: string

Access type: Read-only

Name associated with a particular provider instance. The name is identical to the __Win32Provider property.

This property is inherited from Msft_WmiProvider_OperationEvent

SECURITY_DESCRIPTOR

Data type: uint8 array

Access type: Read-only

Descriptor that the event provider uses to determine which users can receive the event. For more information, see WMI Security Constants.

This property is inherited from __Event.

SuperclassName

Data type: string

Access type: Read-only

Specifies a parent class name, if not blank or NULL. Only classes that are subclasses of this class are returned. If NULL or blank, and Flags contains WBEM_FLAG_SHALLOW, only top-level classes, that is, those which have no parent class are returned. If it is NULL or blank and Flags is WBEM_FLAG_DEEP, all classes within the namespace are returned.

TIME_CREATED

Data type: uint64

Access type: Read-only

Unique value that indicates the time the event is generated. This is a 64-bit value that represents the number of 100-nanosecond intervals after January 1, 1601. The information is in the Coordinated Universal Time (UTC) format.

For more information about using uint64 values in scripts, see Scripting in WMI.

This property is inherited from __Event.

TransactionIdentifer

Data type: String

Access type: Read-only

The TransactionIdentifer property is for internal use, currently always empty.

This property is inherited from Msft_WmiProvider_OperationEvent.

TransactionIdentifier

Data type: string

Access type: Read-only

Internal use only. The current value is "{00000000-0000-0000-0000-000000000000}".

This property is inherited from Msft_WmiProvider_OperationEvent

User

Data type: string

Access type: Read-only

Particular provider instance, configured for per user initialization.

This property is inherited from Msft_WmiProvider_OperationEvent

Requirements

Minimum supported client
Windows Vista
Minimum supported server
Windows Server 2008
Namespace
Root\CIMV2
MOF
System.mof
DLL
WmiPrvSD.dll

See also

Msft_WmiProvider_OperationEvent_Pre

Provider Event Troubleshooting Classes

MSFT_Providers

WMI Troubleshooting

WMI Troubleshooting

Receiving a WMI Event