Share via


CIM_DisplayController class

Represents the capabilities and management of the display controller.

Important  The DMTF (Distributed Management Task Force) CIM (Common Information Model) classes are the parent classes upon which WMI classes are built. WMI currently supports only the CIM 2.x version schemas.

The following syntax is simplified from Managed Object Format (MOF) code and includes all of the inherited properties.

Syntax

class CIM_DisplayController : CIM_Controller
{
  uint16   Availability;
  string   Caption;
  uint32   ConfigManagerErrorCode;
  boolean  ConfigManagerUserConfig;
  string   CreationClassName;
  string   DeviceID;
  boolean  ErrorCleared;
  string   ErrorDescription;
  datetime InstallDate;
  uint32   LastErrorCode;
  uint32   MaxNumberControlled;
  string   Name;
  string   PNPDeviceID;
  uint16   PowerManagementCapabilities[];
  boolean  PowerManagementSupported;
  uint16   ProtocolSupported;
  string   Status;
  uint16   StatusInfo;
  string   SystemCreationClassName;
  string   SystemName;
  datetime TimeOfLastReset;
  string   Description;
  string   VideoProcessor;
  uint16   VideoMemoryType;
  string   OtherVideoMemoryType;
  uint32   NumberOfVideoPages;
  uint32   MaxMemorySupported;
  uint16   AcceleratorCapabilities[];
  string   CapabilityDescriptions[];
};

Members

The CIM_DisplayController class has these types of members:

  • Properties

Properties

The CIM_DisplayController class has these properties.

AcceleratorCapabilities

Data type: uint16 array

Access type: Read-only

An array of integers indicating the graphics and 3D capabilities of the display controller.

Unknown (0)

Other (1)

Graphics Accelerator (2)

3D Accelerator (3)

PCI Fast Write (4)

MultiMonitor Support (5)

PCI Mastering (6)

Second Monochrome Adapter Support (7)

Large Memory Address Support (8)

Availability

Data type: uint16

Access type: Read-only

Availability and status of the device. Inherited from CIM_LogicalDevice.

Value Meaning
1 (0x1)

Other

2 (0x2)

Unknown

3 (0x3)

Running/Full Power

4 (0x4)

Warning

5 (0x5)

In Test

6 (0x6)

Not Applicable

7 (0x7)

Power Off

8 (0x8)

Off Line

9 (0x9)

Off Duty

10 (0xA)

Degraded

11 (0xB)

Not Installed

12 (0xC)

Install Error

13 (0xD)

Power Save - Unknown

The device is known to be in a power save mode, but its exact status is unknown.

14 (0xE)

Power Save - Low Power Mode

The device is in a power save state but still functioning, and may exhibit degraded performance.

15 (0xF)

Power Save - Standby

The device is not functioning but could be brought to full power quickly.

16 (0x10)

Power Cycle

17 (0x11)

Power Save - Warning

The device is in a warning state, though also in a power save mode.

 

CapabilityDescriptions

Data type: string array

Access type: Read-only

An array of free-form strings providing more detailed explanations for any of the video accelerator features indicated in the capabilities array. Note, each entry of this array is related to the entry in the capabilities array that is located at the same index.

Caption

Data type: string

Access type: Read-only

Short textual description of the object. This property is inherited from CIM_ManagedSystemElement.

ConfigManagerErrorCode

Data type: uint32

Access type: Read-only

Win32 Configuration Manager error code.

Value Meaning
0 (0x0)

Device is working properly.

1 (0x1)

Device is not configured correctly.

2 (0x2)

Windows cannot load the driver for this device.

3 (0x3)

Driver for this device might be corrupted, or the system may be low on memory or other resources.

4 (0x4)

Device is not working properly. One of its drivers or the registry might be corrupted.

5 (0x5)

Driver for the device requires a resource that Windows cannot manage.

6 (0x6)

Boot configuration for the device conflicts with other devices.

7 (0x7)

Cannot filter.

8 (0x8)

Driver loader for the device is missing.

9 (0x9)

Device is not working properly; the controlling firmware is incorrectly reporting the resources for the device.

10 (0xA)

Device cannot start.

11 (0xB)

Device failed.

12 (0xC)

Device cannot find enough free resources to use.

13 (0xD)

Windows cannot verify the device's resources.

14 (0xE)

Device cannot work properly until the computer is restarted.

15 (0xF)

Device is not working properly due to a possible re-enumeration problem.

16 (0x10)

Windows cannot identify all of the resources that the device uses.

17 (0x11)

Device is requesting an unknown resource type.

18 (0x12)

Device drivers must be reinstalled.

19 (0x13)

Failure using the VxD loader.

20 (0x14)

Registry might be corrupted.

21 (0x15)

System failure. If changing the device driver is ineffective, see the hardware documentation. Windows is removing the device.

22 (0x16)

Device is disabled.

23 (0x17)

System failure. If changing the device driver is ineffective, see the hardware documentation.

24 (0x18)

Device is not present, not working properly, or does not have all of its drivers installed.

25 (0x19)

Windows is still setting up the device.

26 (0x1A)

Windows is still setting up the device.

27 (0x1B)

Device does not have valid log configuration.

28 (0x1C)

Device drivers are not installed.

29 (0x1D)

Device is disabled; the device firmware did not provide the required resources.

30 (0x1E)

Device is using an IRQ resource that another device is using.

31 (0x1F)

Device is not working properly; Windows cannot load the required device drivers.

 

ConfigManagerUserConfig

Data type: boolean

Access type: Read-only

If TRUE, the device is using a user-defined configuration. This property is inherited from CIM_LogicalDevice.

CreationClassName

Data type: string

Access type: Read-only

Name of the class or subclass used in the creation of an instance. When used with other key properties of the class, this property allows all instances of the class and its subclasses to be uniquely identified. This property is inherited from CIM_LogicalDevice.

Description

Data type: string

Access type: Read-only

Provides a textual description of the object.

DeviceID

Data type: string

Access type: Read-only

Address or other identifying information to uniquely name the logical device. This property is inherited from CIM_LogicalDevice.

ErrorCleared

Data type: boolean

Access type: Read-only

If TRUE, the error reported in the LastErrorCode property is now cleared. This property is inherited from CIM_LogicalDevice.

ErrorDescription

Data type: string

Access type: Read-only

Free-form string that supplies information about the error recorded in the LastErrorCode property and corrective actions to perform. This property is inherited from CIM_LogicalDevice.

InstallDate

Data type: datetime

Access type: Read-only

Date and time when the object was installed. This property does not need a value to indicate that the object is installed. This property is inherited from CIM_ManagedSystemElement.

LastErrorCode

Data type: uint32

Access type: Read-only

Last error code reported by the logical device. This property is inherited from CIM_LogicalDevice.

MaxMemorySupported

Data type: uint32

Access type: Read-only

Qualifiers: Units ( "Bytes" )

Maximum amount of memory supported, in bytes.

MaxNumberControlled

Data type: uint32

Access type: Read-only

Maximum number of directly addressable entities supported by this controller. A value of 0 should be used if the number is unknown or unlimited.

Name

Data type: string

Access type: Read-only

Label by which the object is known. When subclassed, this property can be overridden to be a key property. This property is inherited from CIM_ManagedSystemElement.

NumberOfVideoPages

Data type: uint32

Access type: Read-only

Number of video pages supported given the current resolutions and available memory.

OtherVideoMemoryType

Data type: string

Access type: Read-only

A string describing the video memory type when the instance's VideoMemoryType property is 1 ("Other").

PNPDeviceID

Data type: string

Access type: Read-only

Win32 Plug and Play device identifier of the logical device. This property is inherited from CIM_LogicalDevice.

Example: "*PNP030b"

PowerManagementCapabilities

Data type: uint16 array

Access type: Read-only

Array of the specific power-related capabilities of a logical device. This property is inherited from CIM_LogicalDevice.

Value Meaning
0 (0x0)

Unknown

1 (0x1)

Not Supported

2 (0x2)

Disabled

3 (0x3)

Enabled

The power management features are currently enabled but the exact feature set is unknown or the information is unavailable.

4 (0x4)

Power Saving Modes Entered Automatically

The device can change its power state based on usage or other criteria.

5 (0x5)

Power State Settable

The SetPowerState method is supported. This method is found on the parent CIM_LogicalDevice class and can be implemented. For more information, see Designing Managed Object Format (MOF) Classes.

6 (0x6)

Power Cycling Supported

The SetPowerState method can be invoked with the PowerState parameter set to 5 (Power Cycle).

7 (0x7)

Timed Power On Supported

The SetPowerState method can be invoked with the PowerState parameter set to 5 (Power Cycle) and Time set to a specific date and time, or interval, for power-on.

 

PowerManagementSupported

Data type: boolean

Access type: Read-only

If TRUE, the device can be power managed, that is, put into a power-save state. This property does not indicate that power management features are currently enabled, or if enabled, which features are supported. For more information, see the PowerManagementCapabilities array.

If FALSE, the integer value 1, for the string "Not Supported", should be the only entry in the PowerManagementCapabilities array. This property is inherited from CIM_LogicalDevice.

ProtocolSupported

Data type: uint16

Access type: Read-only

Protocol used by the controller to access 'controlled' devices. This property is inherited from CIM_Controller. Values are:

Value Meaning
1 (0x1)

Other

2 (0x2)

Unknown

3 (0x3)

EISA

4 (0x4)

ISA

5 (0x5)

PCI

6 (0x6)

ATA/ATAPI

7 (0x7)

Flexible Diskette

8 (0x8)

1496

9 (0x9)

SCSI Parallel Interface

10 (0xA)

SCSI Fibre Channel Protocol

11 (0xB)

SCSI Serial Bus Protocol

12 (0xC)

SCSI Serial Bus Protocol-2 (1394)

13 (0xD)

SCSI Serial Storage Architecture

14 (0xE)

VESA

15 (0xF)

PCMCIA

16 (0x10)

Universal Serial Bus

17 (0x11)

Parallel Protocol

18 (0x12)

ESCON

19 (0x13)

Diagnostic

20 (0x14)

I2C

21 (0x15)

Power

22 (0x16)

HIPPI

23 (0x17)

MultiBus

24 (0x18)

VME

25 (0x19)

IPI

26 (0x1A)

IEEE-488

27 (0x1B)

RS232

28 (0x1C)

IEEE 802.3 10BASE5

29 (0x1D)

IEEE 802.3 10BASE2

30 (0x1E)

IEEE 802.3 1BASE5

31 (0x1F)

IEEE 802.3 10BROAD36

32 (0x20)

IEEE 802.3 100BASEVG

33 (0x21)

IEEE 802.5 Token-Ring

34 (0x22)

ANSI X3T9.5 FDDI

35 (0x23)

MCA

36 (0x24)

ESDI

37 (0x25)

IDE

38 (0x26)

CMD

39 (0x27)

ST506

40 (0x28)

DSSI

41 (0x29)

QIC2

42 (0x2A)

Enhanced ATA/IDE

43 (0x2B)

AGP

44 (0x2C)

TWIRP (two-way infrared)

45 (0x2D)

FIR (fast infrared)

46 (0x2E)

SIR (serial infrared)

47 (0x2F)

IrBus

 

Status

Data type: string

Access type: Read-only

String that indicates the current status of the object. Operational and non-operational status can be defined. Operational status can include "OK", "Degraded", and "Pred Fail". "Pred Fail" indicates that an element is functioning properly, but is predicting a failure (for example, a SMART-enabled hard disk drive).

Nonoperational status can include "Error", "Starting", "Stopping", and "Service". "Service" can apply during disk mirror-resilvering, reloading a user permissions list, or other administrative work. Not all such work is online, but the managed element is neither "OK" nor in one of the other states. This property is inherited from CIM_ManagedSystemElement.

Values include the following:

"OK"

"Error"

"Degraded"

"Unknown"

"Pred Fail"

"Starting"

"Stopping"

"Service"

"Stressed"

"NonRecover"

"No Contact"

"Lost Comm"

StatusInfo

Data type: uint16

Access type: Read-only

State of the logical device. If this property does not apply to the logical device, the value 5 (Not Applicable) should be used. This property is inherited from CIM_LogicalDevice.

Value Meaning
1 (0x1)

Other

2 (0x2)

Unknown

3 (0x3)

Enabled

4 (0x4)

Disabled

5 (0x5)

Not Applicable

 

SystemCreationClassName

Data type: string

Access type: Read-only

Scoping system's CreationClassName. This property is inherited from CIM_LogicalDevice.

SystemName

Data type: string

Access type: Read-only

Scoping system's Name. This property is inherited from CIM_LogicalDevice.

TimeOfLastReset

Data type: datetime

Access type: Read-only

Date and time the controller was last reset (powered down or reinitialized).

VideoMemoryType

Data type: uint16

Access type: Read-only

An integer enumeration indicating the type of video memory.

Unknown (0)

Other (1)

VRAM (2)

DRAM (3)

SRAM (4)

WRAM (5)

EDO RAM (6)

Burst Synchronous DRAM (7)

Pipelined Burst SRAM (8)

CDRAM (9)

3DRAM (10)

SDRAM (11)

SGRAM (12)

VideoProcessor

Data type: string

Access type: Read-only

A free-form string describing the video processor/controller.

Remarks

This documentation is derived from the CIM class descriptions published by the DMTF. Microsoft may have made changes to correct minor errors, conform to Microsoft SDK documentation standards, or provide more information.

Requirements

Namespace

Root\CIMV2

See also

CIM_Controller