Set-SPPowerPointConversionServiceApplication
Configures settings for a PowerPoint Conversion Service application.
Syntax
Set-SPPowerPointConversionServiceApplication
[-Identity] <SPPowerPointConversionServiceApplicationPipeBind>
[-AssignmentCollection <SPAssignmentCollection>]
[-CacheExpirationPeriodInSeconds <UInt32>]
[-MaximumConversionsPerWorker <UInt32>]
[-WorkerKeepAliveTimeoutInSeconds <UInt32>]
[-WorkerProcessCount <UInt32>]
[-WorkerTimeoutInSeconds <UInt32>]
[<CommonParameters>]
Description
Use the Set-SPPowerPointConversionServiceApplication
cmdlet to set properties and settings for an instance of a PowerPoint Conversion Service application that is in a farm.
Examples
--------------------EXAMPLE 1---------------------
Set-SPPowerPointConversionServiceApplication -Identity "MyWorkgroupPPTApp" -CacheExpirationPeriodInSeconds 1200
This example establishes new operational defaults for the conversion cache expiration.
--------------------EXAMPLE 2---------------------
Set-SPPowerPointConversionServiceApplication -Identity "MyWorkgroupPPTApp" -DisableBinaryScan:$false
This example disables binary scanning of documents.
Parameters
-AssignmentCollection
Manages objects for the purpose of proper disposal. Use of objects, such as SPWeb or SPSite, can use large amounts of memory and use of these objects in Windows PowerShell scripts requires proper memory management. Using the SPAssignment object, you can assign objects to a variable and dispose of the objects after they are needed to free up memory. When SPWeb, SPSite, or SPSiteAdministration objects are used, the objects are automatically disposed of if an assignment collection or the Global parameter is not used.
When the Global parameter is used, all objects are contained in the global store.
If objects are not immediately used, or disposed of by using the Stop-SPAssignment
command, an out-of-memory scenario can occur.
Type: | SPAssignmentCollection |
Position: | Named |
Default value: | None |
Required: | False |
Accept pipeline input: | True |
Accept wildcard characters: | False |
Applies to: | SharePoint Server Subscription Edition |
-CacheExpirationPeriodInSeconds
Specifies the maximum time, in seconds, that items remain in the back-end server cache. The default value is 600 seconds (10 minutes).
Type: | UInt32 |
Position: | Named |
Default value: | None |
Required: | False |
Accept pipeline input: | False |
Accept wildcard characters: | False |
Applies to: | SharePoint Server Subscription Edition |
-Identity
Specifies the unique name of this PowerPoint Conversion Service application.
Type: | SPPowerPointConversionServiceApplicationPipeBind |
Position: | 1 |
Default value: | None |
Required: | True |
Accept pipeline input: | True |
Accept wildcard characters: | False |
Applies to: | SharePoint Server Subscription Edition |
-MaximumConversionsPerWorker
Specifies the maximum number of presentations that a conversion worker process can convert before recycling. The default value is 5.
Type: | UInt32 |
Position: | Named |
Default value: | None |
Required: | False |
Accept pipeline input: | False |
Accept wildcard characters: | False |
Applies to: | SharePoint Server Subscription Edition |
-WorkerKeepAliveTimeoutInSeconds
Specifies the maximum time, in seconds, that a conversion worker process can be unresponsive before being terminated. The default value is 120 seconds.
Type: | UInt32 |
Position: | Named |
Default value: | None |
Required: | False |
Accept pipeline input: | False |
Accept wildcard characters: | False |
Applies to: | SharePoint Server Subscription Edition |
-WorkerProcessCount
Specifies the number of active instances of the conversion worker process on each back-end. This value must be less than the Windows Communication Foundation (WCF) connection limit for this computer. The default value is 3.
Type: | UInt32 |
Position: | Named |
Default value: | None |
Required: | False |
Accept pipeline input: | False |
Accept wildcard characters: | False |
Applies to: | SharePoint Server Subscription Edition |
-WorkerTimeoutInSeconds
Specifies the maximum time, in seconds, that a conversion worker process is given for any single conversion. The default is 300 seconds (5 minutes).
Type: | UInt32 |
Position: | Named |
Default value: | None |
Required: | False |
Accept pipeline input: | False |
Accept wildcard characters: | False |
Applies to: | SharePoint Server Subscription Edition |