Disable-PnpDevice
Disables a PnP device.
Syntax
Disable-PnpDevice
[-InstanceId] <String[]>
[-CimSession <CimSession[]>]
[-ThrottleLimit <Int32>]
[-AsJob]
[-PassThru]
[-WhatIf]
[-Confirm]
[<CommonParameters>]
Disable-PnpDevice
-InputObject <CimInstance[]>
[-CimSession <CimSession[]>]
[-ThrottleLimit <Int32>]
[-AsJob]
[-PassThru]
[-WhatIf]
[-Confirm]
[<CommonParameters>]
Description
The Disable-PnpDevice cmdlet disables a Plug and Play (PnP) device. You must use an Administrator account to disable a device.
Examples
Example 1: Disable a device
PS C:\>Disable-PnpDevice -InstanceId 'USB\VID_5986&;PID_0266&;MI_00\7&;1E5D3568&;0000'
This command disables a device that has the specified instance ID.
Parameters
-AsJob
Runs the cmdlet as a background job. Use this parameter to run commands that take a long time to complete.
Type: | SwitchParameter |
Position: | Named |
Default value: | None |
Required: | False |
Accept pipeline input: | False |
Accept wildcard characters: | False |
-CimSession
Runs the cmdlet in a remote session or on a remote computer. Enter a computer name or a session object, such as the output of a New-CimSession or Get-CimSession cmdlet. The default is the current session on the local computer.
Type: | CimSession[] |
Aliases: | Session |
Position: | Named |
Default value: | None |
Required: | False |
Accept pipeline input: | False |
Accept wildcard characters: | False |
-Confirm
Prompts you for confirmation before running the cmdlet.
Type: | SwitchParameter |
Aliases: | cf |
Position: | Named |
Default value: | None |
Required: | False |
Accept pipeline input: | False |
Accept wildcard characters: | False |
-InputObject
Specifies the input object that is used in a pipeline command.
Type: | CimInstance[] |
Position: | Named |
Default value: | None |
Required: | True |
Accept pipeline input: | True |
Accept wildcard characters: | False |
-InstanceId
Specifies an array of unique instance IDs of devices.
Type: | String[] |
Aliases: | DeviceId |
Position: | 0 |
Default value: | None |
Required: | True |
Accept pipeline input: | True |
Accept wildcard characters: | False |
-PassThru
Indicates that this cmdlet returns a WMI error code. By default, this cmdlet does not return a value.
Type: | SwitchParameter |
Position: | Named |
Default value: | None |
Required: | False |
Accept pipeline input: | False |
Accept wildcard characters: | False |
-ThrottleLimit
Specifies the maximum number of concurrent operations that can be established to run the cmdlet.
If this parameter is omitted or a value of 0
is entered, then Windows PowerShell® calculates an optimum throttle limit for the cmdlet based on the number of CIM cmdlets that are running on the computer.
The throttle limit applies only to the current cmdlet, not to the session or to the computer.
Type: | Int32 |
Position: | Named |
Default value: | None |
Required: | False |
Accept pipeline input: | False |
Accept wildcard characters: | False |
-WhatIf
Shows what would happen if the cmdlet runs. The cmdlet is not run.
Type: | SwitchParameter |
Aliases: | wi |
Position: | Named |
Default value: | None |
Required: | False |
Accept pipeline input: | False |
Accept wildcard characters: | False |
Inputs
The Microsoft.Management.Infrastructure.CimInstance
object is a wrapper class that displays Windows Management Instrumentation (WMI) objects.
The path after the pound sign (#
) provides the namespace and class name for the underlying WMI object.
Outputs
This cmdlet generates a WMI error code.
Notes