Update-MgBetaDeviceManagementUserExperienceAnalyticBatteryHealthRuntimeDetail

Update the navigation property userExperienceAnalyticsBatteryHealthRuntimeDetails in deviceManagement

Syntax

Update-MgBetaDeviceManagementUserExperienceAnalyticBatteryHealthRuntimeDetail
      [-ResponseHeadersVariable <String>]
      [-ActiveDevices <Int32>]
      [-AdditionalProperties <Hashtable>]
      [-BatteryRuntimeFair <Int32>]
      [-BatteryRuntimeGood <Int32>]
      [-BatteryRuntimePoor <Int32>]
      [-Id <String>]
      [-LastRefreshedDateTime <DateTime>]
      [-Headers <IDictionary>]
      [-ProgressAction <ActionPreference>]
      [-WhatIf]
      [-Confirm]
      [<CommonParameters>]
Update-MgBetaDeviceManagementUserExperienceAnalyticBatteryHealthRuntimeDetail
      -BodyParameter <IMicrosoftGraphUserExperienceAnalyticsBatteryHealthRuntimeDetails>
      [-ResponseHeadersVariable <String>]
      [-Headers <IDictionary>]
      [-ProgressAction <ActionPreference>]
      [-WhatIf]
      [-Confirm]
      [<CommonParameters>]

Description

Update the navigation property userExperienceAnalyticsBatteryHealthRuntimeDetails in deviceManagement

Permissions

Permission type Permissions (from least to most privileged)
Delegated (work or school account) Not supported
Delegated (personal Microsoft account) Not supported
Application DeviceManagementConfiguration.ReadWrite.All, DeviceManagementManagedDevices.ReadWrite.All,

Parameters

-ActiveDevices

Number of active devices within the tenant. Valid values 0 to 2147483647

Type:Int32
Position:Named
Default value:0
Required:False
Accept pipeline input:False
Accept wildcard characters:False

-AdditionalProperties

Additional Parameters

Type:Hashtable
Position:Named
Default value:None
Required:False
Accept pipeline input:False
Accept wildcard characters:False

-BatteryRuntimeFair

Number of devices whose active runtime is greater than 3 hours but lesser than 5 hours. Valid values 0 to 2147483647

Type:Int32
Position:Named
Default value:0
Required:False
Accept pipeline input:False
Accept wildcard characters:False

-BatteryRuntimeGood

Number of devices whose active runtime is greater than 5 hours. Valid values 0 to 2147483647

Type:Int32
Position:Named
Default value:0
Required:False
Accept pipeline input:False
Accept wildcard characters:False

-BatteryRuntimePoor

Number of devices whose active runtime is lesser than 3 hours. Valid values 0 to 2147483647

Type:Int32
Position:Named
Default value:0
Required:False
Accept pipeline input:False
Accept wildcard characters:False

-BodyParameter

The user experience analytics battery health runtime entity contains count of devices broken down into 3 categories - devices with runtime >5 hours, devices with runtime 3-5 hours and devices with runtime< 3 hours.This API provides the count of devices in these 3 categories. To construct, see NOTES section for BODYPARAMETER properties and create a hash table.

Type:IMicrosoftGraphUserExperienceAnalyticsBatteryHealthRuntimeDetails
Position:Named
Default value:None
Required:True
Accept pipeline input:True
Accept wildcard characters:False

-Confirm

Prompts you for confirmation before running the cmdlet.

Type:SwitchParameter
Aliases:cf
Position:Named
Default value:None
Required:False
Accept pipeline input:False
Accept wildcard characters:False

-Headers

Optional headers that will be added to the request.

Type:IDictionary
Position:Named
Default value:None
Required:False
Accept pipeline input:True
Accept wildcard characters:False

-Id

The unique identifier for an entity. Read-only.

Type:String
Position:Named
Default value:None
Required:False
Accept pipeline input:False
Accept wildcard characters:False

-LastRefreshedDateTime

Recorded date time of this runtime details instance.

Type:DateTime
Position:Named
Default value:None
Required:False
Accept pipeline input:False
Accept wildcard characters:False

-ProgressAction

{{ Fill ProgressAction Description }}

Type:ActionPreference
Aliases:proga
Position:Named
Default value:None
Required:False
Accept pipeline input:False
Accept wildcard characters:False

-ResponseHeadersVariable

Optional Response Headers Variable.

Type:String
Aliases:RHV
Position:Named
Default value:None
Required:False
Accept pipeline input:False
Accept wildcard characters:False

-WhatIf

Shows what would happen if the cmdlet runs. The cmdlet is not run.

Type:SwitchParameter
Aliases:wi
Position:Named
Default value:None
Required:False
Accept pipeline input:False
Accept wildcard characters:False

Inputs

Microsoft.Graph.Beta.PowerShell.Models.IMicrosoftGraphUserExperienceAnalyticsBatteryHealthRuntimeDetails

System.Collections.IDictionary

Outputs

Microsoft.Graph.Beta.PowerShell.Models.IMicrosoftGraphUserExperienceAnalyticsBatteryHealthRuntimeDetails

Notes

COMPLEX PARAMETER PROPERTIES

To create the parameters described below, construct a hash table containing the appropriate properties. For information on hash tables, run Get-Help about_Hash_Tables.

BODYPARAMETER <IMicrosoftGraphUserExperienceAnalyticsBatteryHealthRuntimeDetails>: The user experience analytics battery health runtime entity contains count of devices broken down into 3 categories - devices with runtime > 5 hours, devices with runtime 3-5 hours and devices with runtime < 3 hours.This API provides the count of devices in these 3 categories.

  • [(Any) <Object>]: This indicates any property can be added to this object.
  • [Id <String>]: The unique identifier for an entity. Read-only.
  • [ActiveDevices <Int32?>]: Number of active devices within the tenant. Valid values 0 to 2147483647
  • [BatteryRuntimeFair <Int32?>]: Number of devices whose active runtime is greater than 3 hours but lesser than 5 hours. Valid values 0 to 2147483647
  • [BatteryRuntimeGood <Int32?>]: Number of devices whose active runtime is greater than 5 hours. Valid values 0 to 2147483647
  • [BatteryRuntimePoor <Int32?>]: Number of devices whose active runtime is lesser than 3 hours. Valid values 0 to 2147483647
  • [LastRefreshedDateTime <DateTime?>]: Recorded date time of this runtime details instance.