SMS_EPAlert Server WMI Class
The SMS_EPAlert
Windows Management Instrumentation (WMI) class is an SMS Provider server class in Configuration Manager that represents System Center Endpoint Protection alerts.
The following syntax is simplified from Managed Object Format (MOF) code and includes all inherited properties.
Syntax
Class SMS_EPAlert : SMS_AlertBase
{
UInt32 AlertState;
String ClosedBy;
String Comments;
DateTime DateAlertStateModified;
DateTime DateCreated;
DateTime DateFirstActivated;
DateTime DateLastModified;
Boolean Deletable;
Boolean Enabled;
UInt32 FeatureArea;
UInt32 FeatureGroup;
UInt32 ID;
String InstanceNameParam1;
String InstanceNameParam2;
String InstanceNameParam3;
Boolean IsIgnored;
String LastModifiedBy;
Boolean MonitoredByScom;
String Name;
UInt32 NumberOfSubscription;
UInt32 ObjectTypeID;
UInt32 OccurrenceCount;
String ParameterValues;
String RootCauseMessage;
SInt32 RuleState;
UInt32 Severity;
DateTime SkipUntil;
String SourceSiteCode;
UInt32 TypeID;
String TypeInstanceID;
};
Methods
The following table lists the methods in the SMS_EPAlert
class.
Method | Description |
---|---|
Close Method in Class SMS_EPAlert | Closes the alert. |
Properties
AlertState
Data type: UInt32
Access type: Read-only
Qualifiers: [read, valuemap, values]
Current state of this alert.
Value | Alert state |
---|---|
0 | Active |
1 | Postponed |
2 | Canceled |
3 | Unknown |
4 | Disabled |
5 | Never Triggered |
ClosedBy
Data type: String
Access type: Read-only
Qualifiers: [read]
Person who last closed alert, or 'SYSTEM' if canceled.
Comments
Data type: String
Access type: Read/Write
Qualifiers: none
Administrator-supplied comments for this alert.
DateAlertStateModified
Data type: DateTime
Access type: Read-only
Qualifiers: [read]
Date the alert state was last changed.
DateCreated
Data type: DateTime
Access type: Read-only
Qualifiers: [read]
Date the instance was created.
DateFirstActivated
Data type: DateTime
Access type: Read-only
Qualifiers: [read]
Date the alert was first activated.
DateLastModified
Data type: DateTime
Access type: Read-only
Qualifiers: [read]
Date the alert was last changed.
Deletable
Data type: Boolean
Access type: Read/Write
Qualifiers: none
true
if this alert can be deleted.
Enabled
Data type: Boolean
Access type: Read/Write
Qualifiers: none
true
if this alert is enabled. When the alert isn't enabled, the condition isn't evaluated.
FeatureArea
Data type: UInt32
Access type: Read-only
Qualifiers: [read]
The related feature area.
FeatureGroup
Data type: UInt32
Access type: Read-only
Qualifiers: [read, valuemap, values]
A feature group is a set of one or more feature areas.
Value | Feature group |
---|---|
1 | Administration |
2 | Resources |
3 | Deployment |
4 | Monitoring |
5 | Reporting |
ID
Data type: UInt32
Access type: Read-only
Qualifiers: [key, key, read]
Unique identifier for this instance.
InstanceNameParam1
Data type: String
Access type: Read-only
Qualifiers: [read]
The 1st parameter of the linked instance name.
InstanceNameParam2
Data type: String
Access type: Read-only
Qualifiers: [read]
The 2nd parameter of the linked instance name.
InstanceNameParam3
Data type: String
Access type: Read-only
Qualifiers: [read]
The 3rd parameter of the linked instance name.
IsIgnored
Data type: Boolean
Access type: Read-only
Qualifiers: [read]
Whether the current user ignores this alert.
This information applies to System Center 2012 Configuration Manager SP1 or later, and System Center 2012 R2 Configuration Manager or later.
LastModifiedBy
Data type: String
Access type: Read-only
Qualifiers: [read]
Person who last modified the alert.
MonitoredByScom
Data type: Boolean
Access type: Read/Write
Qualifiers: none
Whether the Operations Manager monitors this alert.
Name
Data type: String
Access type: Read/Write
Qualifiers: none
The name of the alert.
NumberOfSubscription
Data type: UInt32
Access type: Read-only
Qualifiers: [read]
The number of subscriptions to this alert.
ObjectTypeID
Data type: UInt32
Access type: Read-only
Qualifiers: [read]
The secured object type id.
OccurrenceCount
Data type: UInt32
Access type: Read-only
Qualifiers: [read]
The number of times this alert has been activated.
ParameterValues
Data type: String
Access type: Read/Write
Qualifiers: none
The values of administrator-defined parameters, such as thresholds. These values are stored in XML format.
RootCauseMessage
Data type: String
Access type: Read-only
Qualifiers: [read]
The root cause of the alert.
RuleState
Data type: SInt32
Access type: Read-only
Qualifiers: [read, valuemap, values]
State of the underlying condition.
Value | Rule state |
---|---|
0 | Bad |
1 | Good |
2 | Unknown |
Severity
Data type: UInt32
Access type: Read/Write
Qualifiers: [valuemap, values]
The impact of this alert.
Value | Severity |
---|---|
1 | Error |
2 | Warning |
3 | Informational |
SkipUntil
Data type: DateTime
Access type: Read/Write
Qualifiers: none
The evaluation isn't starting until the specified time.
SourceSiteCode
Data type: String
Access type: Read/Write
Qualifiers: none
The site code of the source site. For some non-SLA alerts, NULL means it's a global SLA alert.
TypeID
Data type: UInt32
Access type: Read/Write
Qualifiers: [not_null]
Identifier for this type of alert.
TypeInstanceID
Data type: String
Access type: Read-only
Qualifiers: [read]
User-defined identifier. The combination of TypeID
and TypeInstanceID
must be unique.
Remarks
Requirements
Runtime Requirements
For more information, see Configuration Manager Server Runtime Requirements.
Development Requirements