ICorProfilerCallback::AssemblyLoadFinished Method
Notifies the profiler that an assembly has finished loading.
Syntax
HRESULT AssemblyLoadFinished(
[in] AssemblyID assemblyId,
[in] HRESULT hrStatus);
Parameters
assemblyId
[in] Identifies the assembly that was loaded.
hrStatus
[in] An HRESULT that indicates whether the assembly finished loading successfully.
Remarks
The value of assemblyId
is not valid for an information request until the AssemblyLoadFinished
method is called.
Some parts of loading the assembly might continue after the AssemblyLoadFinished
callback. A failure HRESULT in hrStatus
indicates a failure. However, a success HRESULT in hrStatus
indicates only that the first part of loading the assembly has succeeded.