ICorDebugManagedCallback::LogSwitch Method

Notifies the debugger that a common language runtime (CLR) managed thread has called a method in the Switch class to create, modify, or delete a debugging/tracing switch.

Syntax

HRESULT LogSwitch (  
    [in] ICorDebugAppDomain  *pAppDomain,  
    [in] ICorDebugThread     *pThread,  
    [in] LONG                 lLevel,  
    [in] ULONG                ulReason,  
    [in] WCHAR               *pLogSwitchName,  
    [in] WCHAR               *pParentName);  

Parameters

PAppDomain
[in] A pointer to an ICorDebugAppDomain object that represents the application domain containing the managed thread that created, modified, or deleted a debugging/tracing switch.

pThread
[in] A pointer to an ICorDebugThread object that represents the managed thread.

lLevel
[in] A value that indicates the severity level of the descriptive message that was written to the event log.

ulReason
[in] A value of the LogSwitchCallReason enumeration that indicates the operation performed on the debugging/tracing switch.

pLogSwitchName
[in] A pointer to the name of the debugging/tracing switch.

pParentName
[in] A pointer to the name of the parent of the debugging/tracing switch.

Requirements

Platforms: See System Requirements.

Header: CorDebug.idl, CorDebug.h

Library: CorGuids.lib

.NET Framework Versions: Available since 1.0