How to Configure the XML Validator Pipeline Component
The XML Validator pipeline component can be used in any stage (except Disassemble or Assemble) in a send or receive pipeline.
To configure the properties for the XML Validator pipeline component
Drag the XML Validator pipeline component into the Validate stage of a receive pipeline.
In the Properties window, in the Pipeline Component Properties section, set the following.
Use this To do this Document schemas Indicates the namespace and typename of the schema or schemas to be applied to the document. For more information, see How to Use the Schema Collection Property Editor. If no schemas are specified, the run-time schema discovery will be done by using the message's target namespace and root element name information. Note: You may receive a "Two or more of the selected schema share the same target namespace" error if you specify two or more schemas for the Document schemas property.
Default value: Empty collectionRecoverable Interchange Processing When "false" - indicates that entire interchange is validated as a unit (if any contained message fails, entire interchange is suspended).
When "true" - indicates that messages within interchange are extracted individually by validator with possibility of some propagating through messaging pathway and others being suspended.
For more information on recoverable interchange processing, see Recoverable Interchange Processing.