List of iSCSI related hotfixes post SP2 for Windows Server 2008 SP2
List of iSCSI related hotfixes post SP2 for Windows Server 2008 SP2
Applies to:
Windows Server 2008 SP2
Windows Server 2008 Service Pack 2
Note: You should check http://support.microsoft.com for the latest version of the different files.
Note 2: These are not available in Windows Update.
Note 3: You can download them without entering your e-mail address and captcha if you are a Microsoft Premier customer and have a http://Premier.Microsoft.com account.
Note 4: Carefully review the list and decide which might be applicable to your unique environment.
Note 5: Test in your test and your quality assurance environment.
Originally published Jan. 2015. Updated Jan. 2015.
List of iSCSI related hotfixes post SP2 for Windows Server 2008 SP2 as of Jan. 2015:
2789430 Isnscli.exe incorrectly displays IPv6 address information that is from a Windows Server 2008 and Windows Server 2008 R2-based iSNS server
http://support.microsoft.com/kb/2789430
Update(s):
Isns.mof
Isnscli.exe 6.0.6002.23004
Isnsdll.dll 6.0.6002.23004
Isnssrv.dll 6.0.6002.23004
Isnsui.exe 6.0.6002.23004
Isnsuid.dll 6.0.6002.23004
Isnswmi.dll 6.0.6002.23004
2780444 "0x0000012E" Stop error occurs when an application sends a 12-byte SCSI opcode to an iSCSI target in Windows Vista SP2, Windows Server 2008 SP2, Windows 7 SP1, and Windows Server 2008 R2 SP1
http://support.microsoft.com/kb/2780444
Update(s):
Storport.sys 6.0.6002.22969
Supersede(s):
968675 The storport.sys driver leaks nonpaged pool memory when volumes are scanned, mounted, or dismounted in Windows Server 2008 and Windows Vista
2727330 Default gateway is set to 0.0.0.0 if you start a Windows Vista-based, Windows 7-based, Windows Server 2008-based or Windows Server 2008 R2-based computer from an iSCSI boot device
http://support.microsoft.com/kb/2727330
Update(s):
Tcpipreg.sys 6.0.6002.22989
Tcpip.sys 6.0.6002.22989
2710558 Network adapter teaming breaks after you install the hotfix that is described in KB article 2487376 or 2495300 in Windows Vista SP2 or in Windows Server 2008 SP2
http://support.microsoft.com/kb/2710558
Update(s):
Agp440.sys 6.0.6002.22848
Isapnp.sys 6.0.6002.22848
Msisadrv.sys 6.0.6002.22848
Mssmbios.sys 6.0.6002.22848
Nv_agp.sys 6.0.6002.22848
Pci.sys 6.0.6002.22848
Rdpdr.sys 6.0.6002.22848
Streamci.dll 6.0.6002.22848
Swenum.sys 6.0.6002.22848
Termdd.sys 6.0.6002.22848
Uliagpkx.sys 6.0.6002.22848
Volmgr.sys 6.0.6002.22848
Volmgrx.sys 6.0.6002.22848
Note: This is related to 2487376 FIX: Stop error when you replace an iSCSI network adapter or a motherboard by using an identical device on a Windows Server 2008-based or Windows Vista-based computer: "0x0000007B"
2697479 Memory leak in Wmiapsrv.exe on a computer that is running Windows Server 2008, Windows Server 2008 R2, Windows Vista or Windows 7
http://support.microsoft.com/kb/2697479
Update(s):
Wmiprov.dll 6.0.6002.22971
2695321 IPsec session takes 5 to 6 minutes to connect to a storage controller on a computer that is running Windows Vista, Windows Server 2008, Windows 7, or Windows Server 2008 R2
http://support.microsoft.com/kb/2695321
Update(s):
Bfe.dll 6.0.6002.22887
Fwpkclnt.sys 6.0.6002.22887
Fwpuclnt.dll 6.0.6002.22887
Ikeext.dll 6.0.6002.22887
Wfp.mof
Wfp.tmf
Fwpuclnt.dll 6.0.6002.22887
Wfp.mof
2684681 Iscsicpl.exe process stops responding when you try to reconnect a storage device to a computer that is running Windows Vista, Windows Server 2008, Windows 7, or Windows Server 2008 R2
http://support.microsoft.com/kb/2684681
Update(s):
Iscsilog.dll 6.0.6002.22814
Msiscsi.sys 6.0.6002.22814
Supersede(s):
2028982 "0x0000000A" Stop error message in Windows Vista or in Windows Server 2008 if iSCSI storage is installed
http://support.microsoft.com/kb/2028982
981357 The handle count of the system process keeps increasing in Windows Server 2008, in Windows Vista, in Windows 7 or in Windows Server 2008 R2
http://support.microsoft.com/kb/981357
979551 "0x0000000A" error message when you use CHAP authentication to start a computer that is running Windows Vista or Windows Server 2008 from an iSCSI device
http://support.microsoft.com/kb/979551
975773 Error message when you start a computer that is running Windows Vista or Windows Server 2008 from iSCSI by using CHAP authentication: "Stop 0x0000000A"
http://support.microsoft.com/kb/975773
974201 Stop error message when you retrieve WMI connection statistics for iSCSI after you change the iSCSI configurations on a computer that is running Windows Server 2008 or Windows Vista: "0x00000019 BAD_POOL_HEADER"
http://support.microsoft.com/kb/974201
971443 An iSCSI target is not recognized as an installation target when you try to install Windows Server 2008 by using an IPv6 connection
http://support.microsoft.com/kb/971443
970658 iSCSI Initiator dialog box displays a reconnecting session status after you disconnect and then reconnect the physical connection to the iSCSI target on a computer that is running Windows Server 2008 or Windows Vista
http://support.microsoft.com/kb/970658
970312 A crash dump file is not generated as expected when you use certain iSCSI network adapters on a Windows Server 2008-based computer
2652137 FIX: Communications fail when you try to use the Windows Server 2008 R2 provider package to communicate with a Windows Server 2012 iSCSI target
http://support.microsoft.com/kb/2652137
Update(s):
Strgprvdmgmt.mfl
Strgprvdmgmt.dll 6.2.9200.16384
Strgprvdmgmt.mof
Wtvdsprov.dll 6.2.9200.16384
Wtsnapshotprovider.dll 6.2.9200.16384
Wtvdsprov.dll.mui 6.2.9200.16384
Wtsnapshotprovider.dll.mui 6.2.9200.16384
2487376 FIX: Stop error when you replace an iSCSI network adapter or a motherboard by using an identical device on a Windows Server 2008-based or Windows Vista-based computer: "0x0000007B"
http://support.microsoft.com/kb/2487376
Update(s):
Agp440.sys 6.0.6002.22567
Isapnp.sys 6.0.6002.22567
Msisadrv.sys 6.0.6002.22567
Mssmbios.sys 6.0.6002.22567
Nv_agp.sys 6.0.6002.22567
Pci.sys 6.0.6002.22567
Rdpdr.sys 6.0.6002.22567
Streamci.dll 6.0.6002.22567
Swenum.sys 6.0.6002.22567
Termdd.sys 6.0.6002.22567
Uliagpkx.sys 6.0.6002.22567
Volmgr.sys 6.0.6002.22567
2487376 A memory leak occurs in the Wmiprvse.exe process when you query an iSCSI WMI class in Windows Vista or in Windows Server 2008
http://support.microsoft.com/kb/2487376
Update(s):
Iscsicli.exe 6.0.6002.22229
Iscsidsc.dll 6.0.6002.22229
Iscsied.dll 6.0.6002.22229
Iscsiexe.dll 6.0.6002.22229
Iscsium.dll 6.0.6002.22229
Iscsiwmi.dll 6.0.6002.22229
Supersede(s):
974780 Error message when you log on to an iSCSI target by using the Iscsicpl.exe tool on a computer that is running an Itanium-based version of Windows Server 2008 if CHAP authentication is enabled: "Invalid access to memory location"
967999 Stop error message when you start a Windows Server 2008-based computer from an iSCSI boot device that is connected over MPIO paths:"Stop 0x0000007E"
http://support.microsoft.com/kb/967999
Update(s):
Disk.sys 6.0.6002.22756