List of iSCSI related hotfixes post SP1 for Windows Server 2008 R2 SP1
List of iSCSI related hotfixes post SP1 for Windows Server 2008 R2 SP1
Applies to:
Windows Server 2008 R2 SP1
Windows Server 2008 R2 Service Pack 1
Note: You should check http://support.microsoft.com for the latest version of the different files.
Note 2: These are not available in Windows Update.
Note 3: You can download them without entering your e-mail address and captcha if you are a Microsoft Premier customer and have a http://Premier.Microsoft.com account.
Note 4: Carefully review the list and decide which might be applicable to your unique environment.
Note 5: Test in your test and your quality assurance environment.
Originally published Jan. 2015. Updated Jan. 2015.
List of iSCSI related hotfixes post SP1 for Windows Server 2008 R2 SP1 as of Jan. 2015:
2957560 W2K8R2 Windows freezes or loses cluster disk reservation during a stress test in iSCSI initiator
http://support.microsoft.com/kb/2957560
Update(s):
Iscsilog.dll 6.1.7600.16385
Msiscsi.sys 6.1.7601.22647
2908783 Data corruption occurs on iSCSI LUNs in Windows
http://support.microsoft.com/kb/2908783
Update(s):
Iscsilog.dll 6.1.7600.16385
Msiscsi.sys 6.1.7601.18386
Iscsilog.dll 6.1.7600.16385
Msiscsi.sys 6.1.7601.22589
Diskdump.sys 6.1.7601.18386
Diskdump.sys 6.1.7601.22589
Iologmsg.dll 6.1.7601.18386
Iologmsg.dll 6.1.7601.22589
Storport.sys 6.1.7601.18386
Storport.sys 6.1.7601.22589
Iologmsg.dll 6.1.7601.18386
Iologmsg.dll 6.1.7601.22589
Supersede(s):
2780444 "0x0000012E" Stop error occurs when an application sends a 12-byte SCSI opcode to an iSCSI target in Windows Vista SP2, Windows Server 2008 SP2, Windows 7 SP1, and Windows Server 2008 R2 SP1
http://support.microsoft.com/kb/2780444
Update(s):
Storport.sys 6.1.7601.17993
Storport.sys 6.1.7601.22155
2684681 Iscsicpl.exe process stops responding when you try to reconnect a storage device to a computer that is running Windows Vista, Windows Server 2008, Windows 7, or Windows Server 2008 R2
http://support.microsoft.com/kb/2684681
Msiscsi.sys 6.1.7601.17792
Iscsilog.dll 6.1.7600.16385
Msiscsi.sys 6.1.7601.21938
2673977 "0x0000000A" Stop error when you disable a network adapter that is used for iSCSI in Windows 7 or in Windows Server 2008 R2
http://support.microsoft.com/kb/2673977
Msiscsi.sys 6.1.7601.17774
Msiscsi.sys 6.1.7601.21917
2819485 A hotfix that logs an event for the errors that are resulted from dropped frames or dropped requests in Windows 7 or Windows Server 2008 R2 is available
http://support.microsoft.com/kb/2819485
Update(s):
Classpnp.sys 6.1.7601.22269
Iologmsg.dll 6.1.7601.22269 (updated in KB 2908783)
2789430 Isnscli.exe incorrectly displays IPv6 address information that is from a Windows Server 2008 and Windows Server 2008 R2-based iSNS server
http://support.microsoft.com/kb/2789430
Update(s):
Isns.mof
Isnscli.exe 6.1.7600.21391
Isnsdll.dll 6.1.7600.16385
Isnssrv.dll 6.1.7600.16385
Isnsui.exe 6.1.7600.16385
Isnsuid.dll 6.1.7600.16385
Isnswmi.dll 6.1.7600.16385
Isns.mof
Isnscli.exe 6.1.7601.22182
Isnsdll.dll 6.1.7601.17514
Isnssrv.dll 6.1.7601.17514
Isnsui.exe 6.1.7601.17514
Isnsuid.dll 6.1.7601.17514
Isnswmi.dll 6.1.7601.17514
2727330 Default gateway is set to 0.0.0.0 if you start a Windows Vista-based, Windows 7-based, Windows Server 2008-based or Windows Server 2008 R2-based computer from an iSCSI boot device
http://support.microsoft.com/kb/2727330
Update(s):
Netio.sys 6.1.7601.17939
Netio.sys 6.1.7601.22119
Tcpip.sys 6.1.7600.17130
Fwpkclnt.sys 6.1.7600.21330
Tcpip.sys 6.1.7600.21330
Fwpkclnt.sys 6.1.7601.17939
Tcpip.sys 6.1.7601.17959
Fwpkclnt.sys 6.1.7601.22119
Tcpip.sys 6.1.7601.22119
2718576 MPIO disk is removed unexpectedly when a PR_IN command fails in a Windows Server 2008 R2 environment
http://support.microsoft.com/kb/2718576
Update(s):
Mpio.inf_loc
Mpio.sys 6.1.7600.17037
Mpio.sys 6.1.7600.21229
Mpio.sys 6.1.7601.17858
Mpio.sys 6.1.7601.22014
2697479 Memory leak in Wmiapsrv.exe on a computer that is running Windows Server 2008, Windows Server 2008 R2, Windows Vista or Windows 7
http://support.microsoft.com/kb/2697479
Update(s):
Wmiprov.dll 6.1.7601.21959
2695321 IPsec session takes 5 to 6 minutes to connect to a storage controller on a computer that is running Windows Vista, Windows Server 2008, Windows 7, or Windows Server 2008 R2
http://support.microsoft.com/kb/2695321
Update(s):
Bfe.dll 6.1.7601.22032
Fwpuclnt.dll 6.1.7601.22032
Ikeext.dll 6.1.7601.22032
Networksecurity-ppdlic.xrm-ms
Nshwfp.dll 6.1.7601.22032
Wfp.mof
Fwpuclnt.dll 6.1.7601.22032
Nshwfp.dll 6.1.7601.22032
Wfp.mof
Supersede(s):
976042 Windows may fail to boot from an iSCSI drive if networking hardware is changed
http://support.microsoft.com/kb/976042
2680097 Iscsilog.dll is not included in the system state backup files on a Windows Server 2008 R2 SP1-based computer
http://support.microsoft.com/kb/2680097
Update(s):
Crypt32.dll 6.1.7601.21935
Cryptsvc.dll 6.1.7601.21935
Drvstore.dll 6.1.7601.21935
Setupapi.dll 6.1.7601.21935
Setupapi.mof
Wowreg32.exe 6.1.7600.16385
Setupapi.dll 6.1.7601.21935
Setupapi.mof
Wowreg32.exe 6.1.7600.16385
2662288 A differencing VHD file that is created by using Microsoft iSCSI Software Target 3.3 becomes corrupted when you mount or attach it in Windows Server 2008 R2 or in Windows 7
http://support.microsoft.com/kb/2662288
Update(s):
Vhdmp.sys 6.1.7601.17756
Vhdmp.sys 6.1.7601.21891
2652137 FIX: Communications fail when you try to use the Windows Server 2008 R2 provider package to communicate with a Windows Server 2012 iSCSI target
http://support.microsoft.com/kb/2652137
Update(s):
Strgprvdmgmt.mfl
Strgprvdmgmt.dll 6.2.9200.16384
Strgprvdmgmt.mof
Wtvdsprov.dll 6.2.9200.16384
Wtsnapshotprovider.dll 6.2.9200.16384
Wtvdsprov.dll.mui 6.2.9200.16384
Wtsnapshotprovider.dll.mui 6.2.9200.16384
2550978 "0x0000007B" Stop error after you replace an identical iSCSI network adapter in Windows Server 2008 R2 SP1 or in Windows 7 SP1
http://support.microsoft.com/kb/2550978
Update(s):
Pci.sys 6.1.7601.17630
Termdd.sys 6.1.7601.17514
Volmgr.sys 6.1.7601.17514
Pci.sys 6.1.7601.21744
Termdd.sys 6.1.7601.17514
Volmgr.sys 6.1.7601.21744