Share via


FIM Troubleshooting: PCNS received an RPC exception attempting to deliver


PROBLEM STATEMENT

The PCNS service on a domain controller reports the following event trying to do a password synchronization.

 

APPLICATION EVENT LOG

Log Name: Application

Source: PCNSSVC

Date: 4/8/2013 10:43:46 AM

Event ID: 6025

Task Category: (4)

Level: Error

Keywords: Classic

User: N/A

Computer: DC01.contoso.com

Description: Password Change Notification Service received an RPC exception attempting to deliver a notification.

The password change notification target could not be contacted.

User Action:

The target server may not be running. Verify that the target server is running. 

 

Additional Details: 

Thread ID: 2820

Tracking ID: cd8c1bd0-9f2d-4532-bd74-1f5393776694

User GUID: bb5b1897-11fa-4297-aece-347ffcecdde3

User: CONTOSO\User1

Target: FIMSync01

Delivery Attempts: 1

Queued Notifications: 1

***0x000006D9 - There are no more endpoints available from the endpoint mapper. ***


****ProcessID is 4420

System Time is: 4/8/2013 14:43:46:684

Generating component is 2

Status is 1753 - There are no more endpoints available from the endpoint mapper.

Detection location is 501

Flags is 0

NumberOfParameters is 4

Unicode string: ncacn_ip_tcp

Unicode string: FIMSync01.contoso.com

Long val: -647262927

Long val: 382312662

 


CAUSE

Password Synchronization was disabled on the FIM Synchronization server.

 


RESOLUTION:

Enable password synchronization on the sync server.

https://microsoft.sharepoint.com/teams/iamsupport/iamblog/Lists/Photos/040813_1615_PCNSreceive1.png

https://microsoft.sharepoint.com/teams/iamsupport/iamblog/Lists/Photos/040813_1615_PCNSreceive2.png 


ADDITIONAL INFORMATION