Freigeben über


LINECONFIGDATA (Windows CE 5.0)

Send Feedback

This structure specifies the configuration information for a modem line. It is used by the Unimodem Configuration dialog box.

typedef struct _LINECONFIGDATA {DWORD dwVersion;DWORD dwBaudRate;DWORDdwSettableBaud;BYTEbByteSize;BYTEbParity;BYTEbStopBits;BYTEbReserved;WORDwSettableData;WORDwWaitBong;DWORDdwCallSetupFailTimer;DWORDdwModemOptions;DWORDdwTermOptions;DWORDdwDdevCapFlags;DWORDdwModMaxLen;TCHARszDialModifier[NETUI_LCD_DIAL_MOD_LEN + 1];WORDwSettableStopParity;} LINECONFIGDATA, *PLINECONFIGDATA;

Members

  • dwVersion
    Specifies the version of the structure.
  • dwBaudRate
    Specifies the baud rate of the connection, using CBR_* values listed in %_WINCEROOT%\Public\Sdk\Inc\Winbase.h, for example, CBR_110.
  • dwSettableBaud
    Specifies the baud rates, using BAUD_* bit values from %_WINCEROOT%\Public\Sdk\Inc\Winbase.h.
  • bByteSize
    Specifies the number of bits per byte, which can be from 4 to 8.
  • bParity
    Specifies the parity of the connection. The following table shows the parity settings.
    Setting Parity
    0 None
    1 Odd
    2 Even
    3 Mark
    4 Space
  • bStopBits
    Specifies the number of stop bits. The following table shows the settings for stop bits.
    Setting Stop bits
    0 1 stop bit
    1 1.5 stop bits
    2 2 stop bits
  • bReserved
    Used for alignment purposes.
  • wSettableData
    Indicates the number of data bits to be sent. The following table shows the supported values.
    Value Description
    DATABITS_5 5 data bits
    DATABITS_6 6 data bits
    DATABITS_7 7 data bits
    DATABITS_8 8 data bits
    DATABITS_16 16 data bits
    DATABITS_16X Special wide path through serial hardware lines
  • wWaitBong
    Specifies the number of seconds to wait for a credit-card tone.
  • dwCallSetupFailTimer
    Specifies the dial timeout value.
  • dwModemOptions
    Specifies modem options. The following table shows the supported modem options.
    Value Description
    NETUI_LCD_MDMOPT_SOFT_FLOW Software flow control
    NETUI_LCD_MDMOPT_HARD_FLOW Hardware flow control
    NETUI_LCD_MDMOPT_BLIND_DIAL Blind dial
    NETUI_LCD_MDMOPT_AUTO_BAUD Enables DCC automatic baud rate detection
  • dwTermOptions
    Specifies the terminal type. The following table shows the supported terminal types.
    Terminal option Terminal type
    NETUI_LCD_TRMOPT_MANUAL_DIAL Manual dial
    NETUI_LCD_TRMOPT_PRE_DIAL Predial
    NETUI_LCD_TRMPOT_POST_DIAL Postdial
  • dwDdevCapFlags
    Not supported.
  • dwModMaxLen
    Specifies the length to allow user to edit. The length is the value specified for NETUI_LCD_DIAL_MOD_LEN.
  • szDialModifier
    Specifies an optional modem command that is issued just after the modem has been initialized and just before the phone number is to be dialed.
  • wSettableStopParity
    Specifies the stop bit and parity settings that can be selected. The following table shows the supported values.
    Value Description
    PARITY_EVEN Even parity
    PARITY_MARK Mark parity
    PARITY_NONE No parity
    PARITY_ODD Odd parity
    PARITY_SPACE Space parity
    STOPBITS_10 1 stop bit
    STOPBITS_15 1.5 stop bits
    STOPBITS_20 2 stop bits

Requirements

OS Versions: Windows CE 2.10 and later.
Header: Netui.h.

See Also

Network User Interface Structures | LineConfigEdit | COMMPROP

Send Feedback on this topic to the authors

Feedback FAQs

© 2006 Microsoft Corporation. All rights reserved.