LINECONFIGDATA (Windows CE 5.0)
This structure specifies the configuration information for a modem line. It is used by the Unimodem Configuration dialog box.
typedef struct _LINECONFIGDATA {DWORD dwVersion;DWORD dwBaudRate;DWORDdwSettableBaud;BYTEbByteSize;BYTEbParity;BYTEbStopBits;BYTEbReserved;WORDwSettableData;WORDwWaitBong;DWORDdwCallSetupFailTimer;DWORDdwModemOptions;DWORDdwTermOptions;DWORDdwDdevCapFlags;DWORDdwModMaxLen;TCHARszDialModifier[NETUI_LCD_DIAL_MOD_LEN + 1];WORDwSettableStopParity;} LINECONFIGDATA, *PLINECONFIGDATA;
Members
- dwVersion
Specifies the version of the structure. - dwBaudRate
Specifies the baud rate of the connection, using CBR_* values listed in %_WINCEROOT%\Public\Sdk\Inc\Winbase.h, for example, CBR_110. - dwSettableBaud
Specifies the baud rates, using BAUD_* bit values from %_WINCEROOT%\Public\Sdk\Inc\Winbase.h. - bByteSize
Specifies the number of bits per byte, which can be from 4 to 8. - bParity
Specifies the parity of the connection. The following table shows the parity settings.Setting Parity 0 None 1 Odd 2 Even 3 Mark 4 Space - bStopBits
Specifies the number of stop bits. The following table shows the settings for stop bits.Setting Stop bits 0 1 stop bit 1 1.5 stop bits 2 2 stop bits - bReserved
Used for alignment purposes. - wSettableData
Indicates the number of data bits to be sent. The following table shows the supported values.Value Description DATABITS_5 5 data bits DATABITS_6 6 data bits DATABITS_7 7 data bits DATABITS_8 8 data bits DATABITS_16 16 data bits DATABITS_16X Special wide path through serial hardware lines - wWaitBong
Specifies the number of seconds to wait for a credit-card tone. - dwCallSetupFailTimer
Specifies the dial timeout value. - dwModemOptions
Specifies modem options. The following table shows the supported modem options.Value Description NETUI_LCD_MDMOPT_SOFT_FLOW Software flow control NETUI_LCD_MDMOPT_HARD_FLOW Hardware flow control NETUI_LCD_MDMOPT_BLIND_DIAL Blind dial NETUI_LCD_MDMOPT_AUTO_BAUD Enables DCC automatic baud rate detection - dwTermOptions
Specifies the terminal type. The following table shows the supported terminal types.Terminal option Terminal type NETUI_LCD_TRMOPT_MANUAL_DIAL Manual dial NETUI_LCD_TRMOPT_PRE_DIAL Predial NETUI_LCD_TRMPOT_POST_DIAL Postdial - dwDdevCapFlags
Not supported. - dwModMaxLen
Specifies the length to allow user to edit. The length is the value specified for NETUI_LCD_DIAL_MOD_LEN. - szDialModifier
Specifies an optional modem command that is issued just after the modem has been initialized and just before the phone number is to be dialed. - wSettableStopParity
Specifies the stop bit and parity settings that can be selected. The following table shows the supported values.Value Description PARITY_EVEN Even parity PARITY_MARK Mark parity PARITY_NONE No parity PARITY_ODD Odd parity PARITY_SPACE Space parity STOPBITS_10 1 stop bit STOPBITS_15 1.5 stop bits STOPBITS_20 2 stop bits
Requirements
OS Versions: Windows CE 2.10 and later.
Header: Netui.h.
See Also
Network User Interface Structures | LineConfigEdit | COMMPROP
Send Feedback on this topic to the authors