Bearbeiten

Freigeben über


Disable-WdacBidTrace

Disables BidTrace for Windows DAC.

Syntax

Disable-WdacBidTrace
       [-PassThru]
       [-InputObject] <CimInstance[]>
       [-CimSession <CimSession[]>]
       [-ThrottleLimit <Int32>]
       [-AsJob]
       [-WhatIf]
       [-Confirm]
       [<CommonParameters>]
Disable-WdacBidTrace
       [-PassThru]
       [-Platform <String>]
       [-Path] <String>
       [-ProcessId <UInt32>]
       [-CimSession <CimSession[]>]
       [-ThrottleLimit <Int32>]
       [-AsJob]
       [-WhatIf]
       [-Confirm]
       [<CommonParameters>]
Disable-WdacBidTrace
       [-PassThru]
       [-Platform <String>]
       -Folder <String>
       [-CimSession <CimSession[]>]
       [-ThrottleLimit <Int32>]
       [-AsJob]
       [-WhatIf]
       [-Confirm]
       [<CommonParameters>]
Disable-WdacBidTrace
       [-PassThru]
       [-IncludeAllApplications]
       [-Platform <String>]
       [-CimSession <CimSession[]>]
       [-ThrottleLimit <Int32>]
       [-AsJob]
       [-WhatIf]
       [-Confirm]
       [<CommonParameters>]

Description

The Disable-WdacBidTrace cmdlet disables Built-in Diagnostics Tracing (BidTrace) for troubleshooting Windows Data Access Components (Windows DAC).

For more information about data access tracing, see Data Access Tracing (Windows 8) on the Microsoft Developer Network.

Examples

Example 1: Disable BidTrace for a 32-bit application

PS C:\> Disable-WdacBidTrace -Path "C:\temp\abc.exe" -Platform "32-bit"

This command disables the BidTrace for the application C:\temp\abc.exe on the 32-bit platform.

Example 2: Disable BidTrace for a 32-bit application by using a Process ID

PS C:\> Disable-WdacBidTrace -Path "C:\temp\abc.exe" -ProcessId 1234 -Platform "32-bit"

This command disables the BidTrace for the application C:\temp\abc.exe on the 32-bit platform, and disables BidTrace for the particular instance of abc.exe that has the Process ID 1234.

Example 3: Disable BidTrace for all native applications in a folder

PS C:\> Disable-WdacBidTrace -Folder "C:\temp"

This command disables the BidTrace for all applications in C:\temp on the native platform.

Example 4: Disable BidTrace for all 64-bit applications

PS C:\> Disable-WdacBidTrace -IncludeAllApplications -Platform "64-bit"

This command disables the BidTrace for all 64-bit applications.

Example 5: Enable and disable BidTrace for a 64-bit application

PS C:\> $BidSetting = Enable-WdacBidTrace -Path "C:\temp\abc.exe" -Platform "64-bit" -PassThru
PS C:\> Disable-WdacBidTrace -InputObject $BidSetting

The first command enables the BidTrace for the 64-bit application C:\temp\abc.exe, and then stores the result in the $BidSetting variable. After you run the first command, you can use abc.exe.

The second command disables BidTrace for the application stored in $BidSetting.

Parameters

-AsJob

Runs the cmdlet as a background job. Use this parameter to run commands that take a long time to complete.

Type:SwitchParameter
Position:Named
Default value:None
Required:False
Accept pipeline input:False
Accept wildcard characters:False

-CimSession

Runs the cmdlet in a remote session or on a remote computer. Enter a computer name or a session object, such as the output of a New-CimSession or Get-CimSession cmdlet. The default is the current session on the local computer.

Type:CimSession[]
Aliases:Session
Position:Named
Default value:None
Required:False
Accept pipeline input:False
Accept wildcard characters:False

-Confirm

Prompts you for confirmation before running the cmdlet.

Type:SwitchParameter
Aliases:cf
Position:Named
Default value:False
Required:False
Accept pipeline input:False
Accept wildcard characters:False

-Folder

Specifies a folder. This cmdlet disables BidTrace for applications under the folder that this parameter specifies.

Type:String
Aliases:ApplicationFolder
Position:Named
Default value:None
Required:True
Accept pipeline input:True
Accept wildcard characters:False

-IncludeAllApplications

Indicates that this cmdlet applies to all applications. If you specify this parameter, the cmdlet disables BidTrace for all applications.

Type:SwitchParameter
Position:Named
Default value:None
Required:True
Accept pipeline input:True
Accept wildcard characters:False

-InputObject

Specifies the input object that is used in a pipeline command.

Type:CimInstance[]
Aliases:BidTrace
Position:0
Default value:None
Required:True
Accept pipeline input:True
Accept wildcard characters:False

-PassThru

Returns an object representing the item with which you are working. By default, this cmdlet does not generate any output.

Type:SwitchParameter
Position:Named
Default value:None
Required:False
Accept pipeline input:False
Accept wildcard characters:False

-Path

Specifies the full path for an application. This cmdlet disables BidTrace for the application that this parameter specifies.

Type:String
Aliases:ApplicationPath
Position:0
Default value:None
Required:True
Accept pipeline input:True
Accept wildcard characters:False

-Platform

Specifies the platform architecture. This cmdlet disables BidTrace for the Windows DAC BidTrace settings that belong to the architecture that this parameter specifies. The acceptable values for this parameter are:

  • 32-bit
  • 64-bit
  • All

The default value is 32-bit on a 32-bit process. The default value is 64-bit on a 64-bit process. If you run this cmdlet in a remote CIM session, this parameter refers to the platform architecture on the remote computer.

Type:String
Accepted values:32-bit, 64-bit, All
Position:Named
Default value:None
Required:False
Accept pipeline input:True
Accept wildcard characters:False

-ProcessId

Specifies a process ID. This cmdlet disables BidTrace for the process that has the ID that this parameter specifies.

Type:UInt32
Position:Named
Default value:None
Required:False
Accept pipeline input:True
Accept wildcard characters:False

-ThrottleLimit

Specifies the maximum number of concurrent operations that can be established to run the cmdlet. If this parameter is omitted or a value of 0 is entered, then Windows PowerShell® calculates an optimum throttle limit for the cmdlet based on the number of CIM cmdlets that are running on the computer. The throttle limit applies only to the current cmdlet, not to the session or to the computer.

Type:Int32
Position:Named
Default value:None
Required:False
Accept pipeline input:False
Accept wildcard characters:False

-WhatIf

Shows what would happen if the cmdlet runs. The cmdlet is not run.

Type:SwitchParameter
Aliases:wi
Position:Named
Default value:False
Required:False
Accept pipeline input:False
Accept wildcard characters:False

Outputs

CimInstance[]