Step by step video on how to fix the SharePoint Workflow issue caused by .NET patch
This post is a continuation of this previous post. It is also an extension of KB4465015. The video assumes you read the previous post and/or KB.
The page to the scripts mentioned in the video can be found here: https://gist.github.com/joerodgers/2302b394796c865818839d843bae2dad
[embed]https://www.youtube.com/watch?v=l25Gp08egC0[/embed]
Comments
- Anonymous
October 12, 2018
Video killed the radio star. Nice media to explain how to fix the .Net issue.- Anonymous
January 16, 2019
(The content was deleted per user request) - Anonymous
January 16, 2019
Rodney, Sean loves you and so do I :)
- Anonymous
- Anonymous
October 13, 2018
Worked perfectly as shown in the video, THANK YOU! - Anonymous
October 16, 2018
The solution worked perfectly. THANKS A LOT - Anonymous
October 16, 2018
Video no longer available? :(- Anonymous
October 17, 2018
I just test it and it is working. Maybe there is some firewall blocking for you.
- Anonymous
- Anonymous
October 17, 2018
Thank's a lot.Very clear, simple and usefull. - Anonymous
October 23, 2018
Worked a treat, fantastic video, thank you - Anonymous
October 24, 2018
We are encountering the below error while executing the script Add-CodeDomAuthorizedTypeToOWSTimerConfig.ps1VERBOSE: Processing server: DE08W3825Get-WmiObject : The RPC server is unavailable. (Exception from HRESULT: 0x800706BA)At C:\Add-CodeDomAuthorizedTypeToOWSTimerConfig.ps1:371 char:52+ $timerServiceConfigPath = Get-WmiObject <<<< -Query "SELECT * FROM Win32_Service WHERE name = 'SPTimerV4'" -ComputerName $computer | SELECT @{Name="PathName"; Expression={$_.PathName.Trim('"')}} + CategoryInfo : InvalidOperation: (:) [Get-WmiObject], COMException + FullyQualifiedErrorId : GetWMICOMException,Microsoft.PowerShell.Commands.GetWmiObjectCommandVERBOSE: Processing server: DE08W3826New-Object : Exception calling ".ctor" with "1" argument(s): "The UNC path should be of the form \server\share."At C:\Add-CodeDomAuthorizedTypeToOWSTimerConfig.ps1:378 char:29+ $fi = New-Object <<<< System.IO.FileInfo( $uncPath ) + CategoryInfo : InvalidOperation: (:) [New-Object], MethodInvocationException + FullyQualifiedErrorId : ConstructorInvokedThrowException,Microsoft.PowerShell.Commands.NewObjectCommandSet-Content : Logon Failure: The target account name is incorrect.At C:\Add-CodeDomAuthorizedTypeToOWSTimerConfig.ps1:401 char:53+ $defaultXml.ToString() | Set-Content <<<< -Path $uncPath + CategoryInfo : WriteError: (\DE08W3826.CONFIG:String) [Set-Content], IOException + FullyQualifiedErrorId : GetContentWriterIOError,Microsoft.PowerShell.Commands.SetContentCommandGet-Content : Cannot find path '\DE08W3826.CONFIG' because it does not exist.At C:\Add-CodeDomAuthorizedTypeToOWSTimerConfig.ps1:405 char:24+ Get-Content <<<< -Path $uncPath | Set-Content -Path "$($uncPath)backup$(Get-Date -Format 'yyyy_MM_dd_hh.mm.ss').config" + CategoryInfo : ObjectNotFound: (\DE08W3826.CONFIG:String) [Get-Content], ItemNotFoundException + FullyQualifiedErrorId : PathNotFound,Microsoft.PowerShell.Commands.GetContentCommand- Anonymous
October 24, 2018
Make sure SP Timer Service is running on server DE08W3826 and run the script again
- Anonymous
- Anonymous
October 28, 2018
Hi Rodney,Can you please confirm that the scripts are ok to run before the application of the .Net Security updates(s)?Thanks.- Anonymous
October 29, 2018
Yes, you can run the scripts before applying the .NET updates.- Anonymous
October 29, 2018
Thankyou
- Anonymous
- Anonymous
- Anonymous
November 01, 2018
Thanks! Worked Perfect! - Anonymous
November 09, 2018
Your solution worked perfectly on all our servers. The Collect Signatures Workflow SharePoint 2010 "Fail on Start" issue has gone! Thanks a lot! - Anonymous
November 19, 2018
The comment has been removed- Anonymous
November 20, 2018
You may have forgotten the closing '}'
- Anonymous
- Anonymous
November 28, 2018
I encountered this in our Dev Env and followed steps and worked great...any harm in running these scripts and changing those .CONFIGS before running the same updates on our Production Servers?- Anonymous
November 28, 2018
Oops sorry, just saw one of the comments above stating that it was ok. My apologies. Thanks again! - Anonymous
November 29, 2018
It should not bring any problems
- Anonymous
- Anonymous
December 01, 2018
We applied all of the windows updates and after applied the scripts. The issue is still not resolved. Any script using an if statement is still having the same issue. Should we have applied the scripts before applying the updates?- Anonymous
December 03, 2018
Any order should work. You may need to open a support case.
- Anonymous