MSTEST0021: Prefer Dispose over TestCleanup methods

Property Value
Rule ID MSTEST0021
Title Prefer Dispose over TestCleanup methods
Category Design
Fix is breaking or non-breaking Non-breaking
Enabled by default No
Default severity Info
Introduced in version 3.4.0
Is there a code fix Yes, starting with 3.7.0

Cause

This rule raises a diagnostic when there is a void [TestCleanup] method or on any [TestCleanup] if the targeted framework supports IAsyncDisposable interface.

Rule description

Using Dispose or DisposeAsync is a more common pattern and some developers prefer to always use this pattern even for tests.

How to fix violations

Replace [TestCleanup] method by Dispose or DisposeAsync pattern.

When to suppress warnings

You usually don't want to suppress warnings from this rule if you decided to opt-in for it.

Note

This rule is opt-in. It's not enabled even when using <MSTestAnalysisMode>All</MSTestAnalysisMode>. For more information about MSTestAnalysisMode, see MSTest code analysis.

Suppress a warning

If you just want to suppress a single violation, add preprocessor directives to your source file to disable and then re-enable the rule.

#pragma warning disable MSTEST0021
// The code that's violating the rule is on this line.
#pragma warning restore MSTEST0021

To disable the rule for a file, folder, or project, set its severity to none in the configuration file.

[*.{cs,vb}]
dotnet_diagnostic.MSTEST0021.severity = none