Upravit

Sdílet prostřednictvím


MsSna_PrintSession3270 Class

Extends a print session.

The following syntax is simplified from MOF code.

Syntax

  
class MsSna_PrintSession3270 : MsSna_PrintSession  
{  
   sint16 JobTermination;  
   sint16 JobTimeoutSecs;  
   boolean JobTimeout;  
   boolean UseGDI;  
   boolean TRNisASCII;  
   boolean CustomTRN;  
   sint32 CustomTRNChar;  
   String LUName;  
   boolean MonitorJob;  
   boolean LineWrap;  
   boolean JobRenderedAtHost;  
};  

Parameters

JobTermination
Data Type: sint16 Access Type: Read/Write

'EndBracket' means the job completes when the print server receives the End Bracket notification—otherwise, the print server spools the job until the session ends. The following table describes the possible values for JobTermination.

Value Description
0 EndBracket
1 UnBind

JobTimeoutSecs
Data Type: sint16 Qualifiers: MINVALUE(0),MAXVALUE(99),UNITS("sec") Access Type: Read/Write

The timeout for terminating 3270 print jobs—use with 'JobTimeout'.

JobTimeout
Data Type: Boolean Access Type: Read/Write

true to indicate whether a time-out will be used; otherwise, false. JobTimeout is most often used with JobTimeoutSecs.

UseGDI
Data Type: Boolean Access Type: Read/Write

true to indicate that the Windows Graphical Device Interface (GDI) is used to format the print job; otherwise, false.

TRNisASCII
Data Type: Boolean Access Type: Read/Write

true to indicate that transparent data from the host is in ASCII and needs no translation from EBCDIC to ASCII; otherwise, false.

CustomTRN
Data Type: Boolean Access Type: Read/Write

true to indicate that a custom transparency byte, such as one other than the IBM standard of 0x35, will be used; otherwise, false.

CustomTRNChar
Data Type: sint32 Qualifiers: MINVALUE(0),MAXVALUE(255)Access Type: Read/Write

The custom transparency byte—use this with 'CustomTRN' set to true.

LUName
Data Type: String Qualifiers: MAXLEN(8), TOUPPERCASEAccess Type: Read/Write

The 3270 printer LU for the print session.

MonitorJob
Data Type: Boolean Access Type: Read/Write

true to cause the print server to send a message to the host stating that the print job completed; otherwise, false.

LineWrap
Data Type: Boolean Access Type: Read/Write

true to line wrap; otherwise, false.

JobRenderedAtHost
Data Type: Boolean Access Type: Read/Write

true to indicate that the print job is rendered at the host rather than by the Host Integration Server Host Print service; otherwise, false.

Remarks

MsSna_PrintSession3270 uses 3270 protocols to communicate with the host.

Requirements

Platforms: Windows Server 2022, Windows Server 2019, Windows Server 2016, Windows 11, and Windows 10

See Also

WMISNA WMI Provider Classes
Administration and Management Programmer's Guide